Dynalon 564715-0025 Acrylic Buret 25 mL
25 mL acrylic buret with straight bore, 0.1 mL graduations and ±0.10 mL tolerance
- TypeAssortments & Kits
- Clear 25 mL capacity for easy volume reading
- Acrylic body resists breakage in lab use
- +/- 0.10 mL tolerance meets Class B accuracy
- 1 mL graduations allow precise measurement control
- 550 mm height fits standard burette stands
Dynalon 25 mL Acrylic Buret
The Dynalon 564715-0025 is a 25 mL acrylic buret designed for laboratory titration and volumetric measurement. Its Class B tolerance of ±0.10 mL supports routine analytical work where certified Class A accuracy is not required. The clear acrylic body resists breakage better than glass, making it suitable for teaching environments and general bench use.
Thermals Noise and Power Draw
As a manual glassware item, the buret operates without any power consumption, electrical noise, or thermal output. The acrylic construction remains dimensionally stable at normal laboratory temperatures and does not generate heat during use. No external energy source or cooling is needed for standard operation.
Build Quality and Connectors
The straight bore design uses a stopcock made from polymethylpentene and polypropylene for chemical compatibility and smooth flow control. Graduations are marked at 0.1 mL increments from 0 to 25 mL for precise reading. A closure of the same polymer materials is included to seal the top when the buret is not in use.
Highlights
- Clear 25 mL capacity for easy volume reading
- Acrylic body resists breakage in lab use
- +/- 0.10 mL tolerance meets Class B accuracy
- 1 mL graduations allow precise measurement control
- 550 mm height fits standard burette stands
Specifications
| Brand | DYNALON |
|---|---|
| Type | Assortments & Kits |
Questions about this item
How do I install the 25 mL acrylic buret and which step is most often done incorrectly?
Mount the buret vertically using a buret clamp on a stand, then attach the supplied Polymethylpentene/Polypropylene stopcock; the step most often missed is ensuring the stopcock bore is fully aligned and leak-tested with water before adding titrant.
What maintenance or replacement will the buret need over time?
Rinse with distilled water after each use, periodically clean the straight bore and stopcock with a buret brush, and replace the Polymethylpentene/Polypropylene stopcock or closure if the plug wears or the seal no longer holds the +/- 0.10 mL tolerance.
What limit appears first during prolonged titration runs with this 25 mL buret?
The Class B tolerance of +/- 0.10 mL combined with 0.1 mL graduation increments is the first limitation; reading error and stopcock drip rate become noticeable before the 25 mL capacity or 550 mm height constrain the workflow.