DELL
DELL PowerEdge T440 5U rack server 2x Xeon Silver 4116 2.1GHz 12-core 64GB DDR4 H330 8x 2.5" trays 2x 750W PSU
A 5U rack server with two 12-core Xeon Silver 4116 CPUs at 2.1 GHz, 64 GB DDR4, H330 controller, eight 2.5-inch trays and dual 750 W power supplies
- TypeRack
- Rack Height5U
- Redundant Hot-swap PowerYes
- CPU TypeIntel Xeon
- CPU Speed2.1GHz (3.0GHz Turbo)
- CPU SocketLGA 3647
- Dual Xeon Silver 4116 processors deliver 24 cores at 2.1 GHz base and 3.0 GHz turbo
- 64 GB DDR4-2400 ECC registered memory installed across four 16 GB modules with room to expand to 1 TB
- PERC H330 12 Gb/s SAS/SATA controller manages up to sixteen 2.5" hot-swap drive bays
- Redundant hot-plug 750 W platinum power supplies keep the 5U rack server running through a single supply failure
- iDRAC 9 Express provides remote lifecycle management without an operating system running
Dual Xeon Silver 4116 5U server
The Dell PowerEdge T440 is a 5U tower server configured with two Intel Xeon Silver 4116 processors running at 2.1 GHz with a 3.0 GHz turbo frequency. Each CPU provides 12 cores for a total of 24 threads, targeting virtualization, database hosting and business-critical workloads. The system ships with 64 GB of DDR4-2400 ECC registered memory across four modules. It is built for organizations that need scalable compute and dense storage in a single chassis.
Redundant 750 W platinum power
Two hot-swap 750 W platinum-efficiency power supplies provide full redundancy for continuous operation. The chassis supports up to sixteen 2.5-inch hot-swap drive bays, with eight drive trays included, allowing storage expansion without downtime. Integrated dual-port Gigabit Ethernet and iDRAC 9 Express remote management keep the server accessible even when the operating system is offline. The PERC H330 controller manages SAS and SATA drives with 12 Gb/s throughput.
Expandable storage and PCIe slots
The server offers sixteen 2.5-inch drive bays so you can add SAS, SATA or SSD media as capacity needs grow. Eight trays are installed; the remaining bays accept standard 2.5-inch hot-swap carriers. PCI Express expansion slots accept RAID controllers, additional network adapters, GPUs or other add-in cards. A rack conversion kit is optional for cabinet deployment. Front bezel and ready rails are not included.
Highlights
- Dual Xeon Silver 4116 processors deliver 24 cores at 2.1 GHz base and 3.0 GHz turbo
- 64 GB DDR4-2400 ECC registered memory installed across four 16 GB modules with room to expand to 1 TB
- PERC H330 12 Gb/s SAS/SATA controller manages up to sixteen 2.5" hot-swap drive bays
- Redundant hot-plug 750 W platinum power supplies keep the 5U rack server running through a single supply failure
- iDRAC 9 Express provides remote lifecycle management without an operating system running
Specifications
| Brand | DELL |
|---|---|
| Series | PowerEdge |
| Model | T440 |
| Type | Rack |
| Rack Height | 5U |
| Redundant Hot-swap Power | Yes |
| CPU Type | Intel Xeon |
| CPU Speed | 2.1GHz (3.0GHz Turbo) |
| CPU Socket | LGA 3647 |
| Number of CPU Cores | 12 Core-Processors |
| CPU Features | Silver 4116 |
| # of Processors Installed | 2 |
| MAX Processors | 2 |
| Installed Memory Size | 64GB |
| Memory Type | DDR4 |
| Max Memory Capacity | 1TB |
| Number of Memory Slots | 16 |
| Hard Drive (Installed) | None |
| Storage Controller | Dell Perc H330 Controller |
| SSD (Installed) | No |
| Raid Level | RAID 0/1/5/10/50 |
| Ethernet Controller | Integrated Dell 2x1GbE Dual Port Ethernet Adapter |
| Remote Management | iDRAC9 Express |
| LAN Ports | 2 x Ports |
| Management Port | RJ 45 |
| Operating System | No |
Questions about this item
How do I install the Xeon Silver 4116 processors into the LGA 3647 sockets?
Align the processor notches with the socket keys, lower the load plate gently, and secure the lever; the step often missed is applying thermal paste evenly before seating the heatsink.
Which components will need replacement first under continuous operation?
The 750 Watt Platinum power supplies and system fans are the primary field-replaceable units; drive trays and memory modules rarely fail but can be swapped hot if required.
What thermal limit appears first when both CPUs run at 3.0 GHz Turbo under sustained load?
The dual 750 W PSU rating and chassis airflow define the power envelope; prolonged Turbo on all 24 cores will hit the thermal design limit before memory bandwidth saturates.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
DELL J1-7490AA01 All-in-One PC Core i7-10700 2.9GHz 16GB 512GB SSD 23.8" FHD
- All-in-One PC
- All-in-One
HP J1-800G6AA01 All-in-One PC Core i5-10500 16GB DDR4 512GB NVMe 23.8
- All-in-One PC
- All-in-One



