Dayton
Dayton Transflow Blower 115 Volt Ceiling Fan
115 V direct-drive blower delivers 201 cfm free air and 187 cfm at .100 in static pressure for ducted ventilation
- typeTransflow
- Delivers 201 cfm free-air flow for strong ventilation
- Maintains 187 cfm at .100 in wc for ducted installs
- Direct-drive design eliminates belt wear and noise
- Sleeve bearings and carbon-steel wheel reduce maintenance needs
- Operates up to 104 °F inlet temperature for harsh environments
Dayton Transflow Blower 115 Volt
The Dayton Transflow blower is a direct-drive ventilation unit built for 115 volt supply. It uses a single-inlet, forward-curved wheel to move air through a rectangular outlet suited to ducting or equipment enclosures.
Airflow 201 cfm free air 90 cfm at 0.250 in wc
At zero static pressure the blower delivers 201 cfm, falling to 187 cfm at 0.100 in wc and 90 cfm at 0.250 in wc. Maximum static pressure is 1/4 in wc, so it handles short duct runs but cannot overcome long or restrictive systems.
Sleeve bearing carbon steel housing 13 inch wheel
The wheel and housing are both C45 carbon steel with a sleeve bearing, rated for inlet air up to 104 Degrees F. The 13 inch wheel width and 1 by 13 5/8 inch outlet provide a broad, shallow discharge that fits slim cabinet slots without extra transitions.
Highlights
- Delivers 201 cfm free-air flow for strong ventilation
- Maintains 187 cfm at .100 in wc for ducted installs
- Direct-drive design eliminates belt wear and noise
- Sleeve bearings and carbon-steel wheel reduce maintenance needs
- Operates up to 104 °F inlet temperature for harsh environments
Specifications
| Brand | Dayton |
|---|---|
| type | Transflow |
Questions about this item
Will this 115 Volt Dayton Transflow blower work with my existing 115 V wiring and controls?
Yes, the blower is rated for 115 Volt operation and uses a direct-drive motor, so it connects directly to a standard 115 V supply without needing a separate drive unit.
How can I verify the blower is performing correctly once installed?
Measure the airflow against the published static-pressure curve: 201 cfm at 0.000 in wc, 187 cfm at 0.100 in wc, and 90 cfm at 0.250 in wc; the maximum static pressure is 1/4 in wc.
What components are included and what must I source separately?
The unit ships fully assembled with the forward-curved carbon-steel wheel, carbon-steel housing, sleeve bearings and rectangular outlet (1 in by 13 5/8 in); you must supply mounting hardware, ducting for the single inlet, and a 115 V power connection.