Dayton
Dayton 5PV48 Hydronic Unit Heater 60,000 BtuH 17-1/8"W
Suspended horizontal hydronic unit heater delivers 60,000 BtuH at 2 PSI steam and 43,600 BtuH at 200°F water with 900 cfm airflow
- 60,000 BtuH steam output delivers powerful heating for large spaces
- 43,600 BtuH water output provides efficient hydronic performance
- 900 cfm airflow ensures effective heat distribution across the area
- 17-1/8" width allows flexible installation in tight mounting locations
- OSHA compliant fan guard protects personnel during operation
Suspended Horizontal Hydronic Heater
This Dayton unit heater mounts on a wall or ceiling and delivers horizontal airflow using steam or water as the heating medium. It produces 60,000 BtuH at 2 PSI steam and 43,600 BtuH at 200 F water with a 900 cfm air flow driven by a 12 in fan. The cabinet measures 20 1/2 in high, 17 1/8 in wide and 10 15/16 in deep and connects through a 1 1/4 in threaded female NPT fitting.
Hydronic Heating for Commercial Spaces
The heater suits facilities that have a central boiler or steam supply and need targeted warmth in a workshop, warehouse or garage. Buyers who require electric resistance heat, gas-fired equipment or a vertical discharge pattern should consider other product types.
Steam and Water Output Ratings
The single specification that determines fit is the dual output rating of 60,000 BtuH with steam and 43,600 BtuH with 200 F water. If the available hydronic loop cannot meet either condition the unit will not deliver the stated capacity.
Highlights
- 60,000 BtuH steam output delivers powerful heating for large spaces
- 43,600 BtuH water output provides efficient hydronic performance
- 900 cfm airflow ensures effective heat distribution across the area
- 17-1/8" width allows flexible installation in tight mounting locations
- OSHA compliant fan guard protects personnel during operation
Specifications
| Brand | DAYTON |
|---|
Questions about this item
At what water temperature does the 60,000 BtuH steam rating drop to 43,600 BtuH?
The heater delivers 60,000 BtuH at 2 PSI steam and 43,600 BtuH at 200 F water.
How loud is the 12-inch fan when the unit runs continuously at 900 cfm?
The 12-inch fan with OSHA-compliant guard moves 900 cfm at 1.4 amps on single-phase power.
What piping connection does the 1-1/4 inch threaded female NPT require on the supply side?
The coil uses a 1-1/4 inch threaded female NPT connection for steam or water supply.