Dayton
Dayton 4YC64 Downblast Vent Trap, Direct Drive, 8-1/4 In, 60 Hz
Centrifugal downblast roof exhaust fan with direct-drive motor delivering 374 cfm airflow at 115V AC
- TypeDrain Components
- Direct-drive design eliminates belt maintenance
- 374 cfm airflow at zero static pressure
- 1/30 hp motor runs on standard 115 V single-phase power
- Square 19-inch roof curb simplifies installation
- Rated for clean-air exhaust in low-static applications
Downblast Vent for Roof Mounting
This downblast vent is a direct-drive exhaust fan assembled for roof installation. It moves 374 cfm of clean air at zero static pressure and operates on a 115V AC single-phase supply. The unit includes the motor and drive package in a square 19-inch base.
Installers needing a compact direct-drive exhaust
The fan suits contractors fitting a low-horsepower roof vent where a 1/30 hp motor and 3/8 in wc maximum static pressure meet the system demand. It is not for ducts requiring higher airflow, greater static-pressure capability or three-phase power.
374 cfm at zero static pressure
This single airflow figure at .000 in SP determines whether the vent can satisfy the ventilation load. If the design calls for more capacity or higher pressure, a different unit is required.
Highlights
- Direct-drive design eliminates belt maintenance
- 374 cfm airflow at zero static pressure
- 1/30 hp motor runs on standard 115 V single-phase power
- Square 19-inch roof curb simplifies installation
- Rated for clean-air exhaust in low-static applications
Specifications
| Type | Drain Components |
|---|---|
| Brand | Dayton |
| Model | 4YC64 |
Questions about this item
Does the 4YC64 arrive fully assembled with the motor and drive package included?
Yes, the unit is supplied assembled and includes both the motor and the drive package so no separate motor or drive components need to be purchased.
Which voltage and frequency version should be selected for a standard North American 115 V, 60 Hz supply?
The nameplate is rated 115 V AC single-phase at 60 Hz, matching typical residential and light-commercial circuits in North America.
What airflow can be expected at zero static pressure when the fan is installed on a roof?
At 0.000 in wc static pressure the fan delivers 374 cfm of clean air exhaust in a roof-mounted configuration.