We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Dayton

Dayton 4P913 Turbine Pump 1/2 HP 115/230V

SKU CH-1RH7-B760A MPN 4P913

A turbine pump delivering up to 40 gpm at 170 psi shut-off pressure with 1/2 hp motor for 115/230V operation

  • TypeDrain Components
  • Delivers up to 40 gpm maximum flow for high-volume drainage
  • Achieves 700 ft maximum head to overcome tall vertical lifts
  • Provides 170 psi shut-off pressure for strong system performance
  • Runs on 115/230V single-phase power for flexible installation
  • Maintains steady output with 4.3 gpm at 10 psi operating point

Turbine pump for drainage applications

The Dayton 4P913 is a single-phase turbine pump rated at one-half horsepower and designed for drain and trap installations. It operates on 115/230V AC power with a capacitor-start motor housed in an open dripproof enclosure. The cast-iron housing provides durability for continuous liquid-handling tasks. This unit suits installers who need a reliable pump for moving water through drainage systems.

Cast-iron build with NPT connections

The pump housing uses cast iron for structural strength while the open dripproof motor enclosure allows airflow for cooling. Intake accepts a 1 1/4-inch pipe and discharge uses a 1-inch NPT connection for standard threaded fittings. Flow rates measure 4.3 gpm at 10 psi, 4.2 gpm at 20 psi and 4.1 gpm at 30 psi. Best efficiency occurs at 112 feet of head for steady operation.

Replaces worn drain pumps in existing lines

This turbine pump upgrades older or failed drain components where a 1/2 hp single-phase motor matches the original specification. The 170 psi shut-off pressure and 700-foot maximum head cover demanding vertical lifts. The jump is worth it when the current pump cannot maintain flow at required pressure or when the motor enclosure has deteriorated. Buyers needing higher flow rates or different voltage configurations should look elsewhere.

Highlights

  • Delivers up to 40 gpm maximum flow for high-volume drainage
  • Achieves 700 ft maximum head to overcome tall vertical lifts
  • Provides 170 psi shut-off pressure for strong system performance
  • Runs on 115/230V single-phase power for flexible installation
  • Maintains steady output with 4.3 gpm at 10 psi operating point

Specifications

TypeDrain Components
BrandDayton
Model4P913

Questions about this item

What does the 115/230V AC single-phase rating mean for circuit sizing?

The motor runs on single-phase power at either 115 V or 230 V AC; wire and breaker must match the voltage you select and the 1/2 hp load.

What pipe sizes and thread type are required for the 1 1/4 in intake and 1 in discharge?

Intake needs 1 1/4 inch pipe, discharge needs 1 inch pipe, both using NPT threads; no other sizes or thread types are compatible.

How is the capacitor-start motor wired during installation, and what step is often missed?

Connect the supply leads to the dual-voltage terminals for 115 V or 230 V, secure the ground, and verify rotation direction before final tightening.