Dayton
Dayton 4A700 Brass Solenoid Valve 3/8 in Normally Closed
Brass two-way solenoid valve, normally closed with 3/8 in ports and a 2.2 Cv rating for air, inert gas or water up to 200 psi and 180 °F
- TypeDrain Components
- Brass body resists corrosion for long service life
- Normally closed design stops flow when de-energised
- 2 Cv rating delivers strong flow capacity
- Handles 200 psi water and air pressure
- Rated to 180 °F fluid temperature for hot-water use
Brass Solenoid Valve 3/8 in
This Dayton 4A700 valve body is a normally closed, two-way brass solenoid designed for drain and trap applications. It accepts a 3/8 inch pipe connection and operates without an integrated coil. The unit suits indoor or outdoor installations where automatic fluid control is required.
Coil-free body changes installation
Because the valve ships less coil, you must supply a compatible solenoid coil that matches your voltage and enclosure needs. The brass body provides a 2.2 Cv flow coefficient and handles air, inert gas or water up to 200 psi differential pressure. Fluid temperature must not exceed 180 degrees Fahrenheit.
Check pressure and chemical warnings
Verify that your system pressure stays above the 2 psi minimum and below the 200 psi maximum for the intended media. The product carries a California Proposition 65 warning for chemicals linked to cancer and reproductive harm. Ensure the installation environment meets the indoor/outdoor rating before ordering.
Highlights
- Brass body resists corrosion for long service life
- Normally closed design stops flow when de-energised
- 2 Cv rating delivers strong flow capacity
- Handles 200 psi water and air pressure
- Rated to 180 °F fluid temperature for hot-water use
Specifications
| Type | Drain Components |
|---|---|
| Brand | Dayton |
| Model | 4A700 |
Questions about this item
Will the brass body or internal seals need replacement after extended use with water at 180 Degrees F?
The brass body and 3/8 in orifice are rated for fluid temperatures up to 180 Degrees F and pressures up to 200 psi, so seal life depends on water quality and cycle frequency at those limits.
What pressure limit is reached first when the valve runs continuously at the maximum 200 psi differential?
Both air/inert gas and water share the same 200 psi maximum operating pressure differential, so that ceiling appears first regardless of the fluid used.
How much heat does the coil generate when the valve stays energised all day at 200 psi?
The coil is sold separately, so its power draw and heat output depend on the specific coil chosen for the 3/8 in brass body.