We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Dayton

Dayton 36VF13 3-Phase Motor 3 HP 143/5TC Frame 230/460V AC

SKU CH-SYNX-N59GW

Three-phase general-purpose motor delivers 3 HP at 3,450 RPM with 85.5 % efficiency in a 143/5TC steel frame

  • TypeMotors
  • 3 HP output for industrial machinery
  • 230/460 V dual-voltage wiring flexibility
  • 143/5TC frame fits standard C-face mounts
  • 5 % nominal efficiency reduces energy cost
  • 15 service factor handles peak loads

Industrial three-phase motor for continuous duty

The Dayton 36VF13 is a general-purpose three-phase AC motor rated at 3 HP with a 143/5TC frame. It operates on 230/460V AC at 60 Hz and carries CSA and UL listings. The open drip-proof enclosure and rigid base suit indoor industrial machinery that runs continuously.

Thermals and electrical draw under load

Class F insulation supports a maximum ambient temperature of 40 degrees Celsius. Nominal efficiency reaches 85.5 percent at a nameplate speed of 3,450 RPM. Full-load current measures 7.1 amps at 230V or 3.5 amps at 460V with a 1.15 service factor for occasional overloads.

Mounting and rotation flexibility included

A C-face mounting flange and steel frame allow direct coupling to pumps, fans or gearboxes. The shaft rotates clockwise or counter-clockwise to match driven equipment. Ball bearings handle radial and axial loads without additional accessories. No thermal protection is built in, so external overload devices are required.

Highlights

  • 3 HP output for industrial machinery
  • 230/460 V dual-voltage wiring flexibility
  • 143/5TC frame fits standard C-face mounts
  • 5 % nominal efficiency reduces energy cost
  • 15 service factor handles peak loads

Specifications

BrandDAYTON
TypeMotors

Questions about this item

How do I wire the 230/460V AC three-phase motor to the terminal box for the correct voltage?

Connect the nine leads for low-voltage 230 V or high-voltage 460 V as shown on the nameplate diagram; the motor draws 7.1 A at 230 V and 3.5 A at 460 V.

What bearing maintenance does the 143/5TC frame motor require over time?

The ball bearings are factory lubricated; plan to re-grease them per the manufacturer's interval based on the 40 °C maximum ambient temperature and continuous duty cycle.

At what load point does the 1.15 service factor limit appear first during sustained operation?

The 1.15 service factor allows 15 % overload for short periods; continuous operation above 3 HP nameplate rating will exceed the thermal design first.