We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Dayton

Dayton 36GK96 Thermocouple Probe Type J 12in 304 SS 19 AWG

SKU CH-X4V3-KCTHX

Type J thermocouple probe with 12.0 in 304 stainless steel sheath, 19 AWG element, ungrounded junction and standard plug for up to 1,650 °F

  • TypeTemperature Controllers
  • Accurate readings to ±1.1 °C below 293 °C
  • Withstands 1,000 psi in harsh environments
  • 0 in probe reaches deep into processes
  • 304 stainless sheath resists corrosion at 1,650 °F
  • Ungrounded 19 AWG element ensures fast response

Dayton 36GK96 Type J Probe

The Dayton 36GK96 is a Type J thermocouple probe built for industrial temperature measurement. Its 12.0 inch 304 stainless steel sheath and 19 AWG element suit process monitoring and control tasks.

Users needing Type J compatibility

Engineers specifying Type J sensors for existing controllers will find this probe a direct fit. Buyers who require Type K, Type T or other calibration standards should select a different probe.

12 inch reach with 1650 °F limit

The magnesium oxide insulated cable handles continuous exposure up to 1650 °F and withstands 1000 psi pressure. Accuracy holds at ±1.1 °C below 293 °C and ±0.4 % above that threshold.

Highlights

  • Accurate readings to ±1.1 °C below 293 °C
  • Withstands 1,000 psi in harsh environments
  • 0 in probe reaches deep into processes
  • 304 stainless sheath resists corrosion at 1,650 °F
  • Ungrounded 19 AWG element ensures fast response

Specifications

BrandDAYTON
TypeTemperature Controllers

Questions about this item

What connector does the 36GK96 probe use to attach to my meter?

The probe ends in a standard plug that fits common Type J thermocouple instruments.

Will the 0.188 in sheath fit through the same port as my older 1/8 in probe?

The 0.188 in sheath is slightly larger than 1/8 in, so verify the port diameter before installing.

How do I confirm the 36GK96 is reading within its ±1.1 °C tolerance below 293 °C?

Place the tip in an ice bath at 0 °C; the meter should show between −1.1 °C and +1.1 °C.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.