Dayton
Dayton 2CZZ5 Brass Solenoid Valve Less Coil, 1/8 in, Normally Closed
A 2-way brass solenoid valve body, normally closed, with a 5/32 in orifice and 0.48 Cv for air, inert gas or water up to 100 psi and 180 °F
- TypeDrain Components
- Brass body resists corrosion for long service life
- Normally closed design stops flow until energised for safety
- 48 Cv rating suits low-flow control applications
- Handles air, inert gas or water up to 100 psi
- Operates in temperatures up to 180 °F indoors or outdoors
Purpose & Fit
The Dayton 2CZZ5 is a two-way, normally closed brass solenoid valve body with a 1/8 inch pipe size and a 5/32 inch orifice. It suits installers and maintenance teams needing a compact valve for air, inert gas or water lines where flow starts only when energised.
What Changes Without a Coil
This listing supplies the valve body only; a compatible coil must be sourced separately to complete the assembly. Selecting the correct voltage and enclosure coil determines whether the unit can be used indoors or outdoors and at what electrical rating.
Install Notes
The 1/8 inch nominal pipe size threads into standard fittings, and the brass body handles up to 180 degrees F fluid temperature with a 100 psi maximum differential for both air and water. Zero psi minimum differential means it operates without upstream pressure, but the separate coil must match the voltage and environmental rating or the valve will not actuate.
Highlights
- Brass body resists corrosion for long service life
- Normally closed design stops flow until energised for safety
- 48 Cv rating suits low-flow control applications
- Handles air, inert gas or water up to 100 psi
- Operates in temperatures up to 180 °F indoors or outdoors
Specifications
| Type | Drain Components |
|---|---|
| Brand | Dayton |
| Model | 2CZZ5 |
Questions about this item
What replacement coil voltage or wattage will this 2CZZ5 valve body require later?
The valve body is sold without a coil, so the replacement coil must match the system voltage and power rating you select for the application.
What pressure limit will be reached first during continuous air or water service?
Both air and water lines are rated to a maximum operating pressure differential of 100 psi, so that limit applies equally.
How hot does the brass body get when the valve cycles all day with 180 °F fluid?
The brass body will approach the fluid temperature of 180 °F during sustained operation, so plan for hot-surface protection.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Taylor Made 12" x 18" Jolly Roger Novelty Flag 1818 marine electronic
- Accessories