Dayton
Dayton 1TDT5 Rectangular OEM Blower 1020 RPM
Direct-drive rectangular OEM blower delivers 965 cfm at free air and 750 cfm at 0.500 in static pressure
- typeHigh Temperature
- Delivers 965 cfm at zero static pressure
- Maintains 950 cfm at 0.100 in SP
- Provides 873 cfm at 0.250 in SP
- Outputs 820 cfm at 0.400 in SP
- Operates at 1020 RPM with direct drive
Dayton 1TDT5 Rectangular OEM Blower
This Dayton 1TDT5 Rectangular OEM Blower delivers 1020 RPM direct-drive airflow for OEM integration. It suits system builders and maintenance teams replacing or specifying a forward-curved wheel blower in industrial or commercial equipment.
Direct-drive assembly requires no belt alignment
The unit ships assembled with a direct-drive package, so installation centres on securing the housing and wiring the single-phase motor. The forward-curved wheel is sensitive to inlet obstructions; restricted intake reduces output and increases motor load.
Confirm static-pressure needs against
Airflow drops from 965 cfm at .000 in SP to 750 cfm at .500 in SP, with intermediate points at 950 cfm (.100), 873 cfm (.250) and 820 cfm (.400). Systems demanding pressure beyond .500 in SP or requiring unmapped points at .125, .375, .750, 1.000 or 1.250 in SP will not match this blower. The product carries a California Proposition 65 warning for cancer and reproductive-harm chemicals.
Highlights
- Delivers 965 cfm at zero static pressure
- Maintains 950 cfm at 0.100 in SP
- Provides 873 cfm at 0.250 in SP
- Outputs 820 cfm at 0.400 in SP
- Operates at 1020 RPM with direct drive
Specifications
| Brand | Dayton |
|---|---|
| type | High Temperature |
Questions about this item
How can I confirm the blower is delivering the rated 965 cfm at zero static pressure after installation?
Measure the airflow at the outlet with a calibrated anemometer; a reading close to 965 cfm at 0.000 in SP shows the unit is performing to spec.
What components are included with the Dayton 1TDT5 and what must be sourced separately?
The blower ships fully assembled with its direct-drive motor and forward-curved wheel; mounting hardware, ducting, wiring and any speed control are not included.
Which airflow rating should I use to match my system’s static pressure — 0.100 in SP or 0.250 in SP?
Choose the rating that matches your duct resistance: 950 cfm at 0.100 in SP for low-restriction runs, 873 cfm at 0.250 in SP for higher-restriction installations.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.