We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Dayton

Dayton 1TDT2 Rectangle Replacement OEM Blower 549 cfm

SKU CH-HWEX-GFHN5

A direct-drive forward-curved blower wheel delivering 549 cfm at zero static pressure and 450 cfm at 0.500 in SP

  • typeHigh Temperature
  • High airflow of 549 cfm at zero static pressure
  • Consistent output of 538 cfm at 0.100 in SP
  • Reliable delivery of 507 cfm at 0.250 in SP
  • Steady performance of 480 cfm at 0.400 in SP
  • Usable flow of 450 cfm at 0.500 in SP

Dayton 1TDT2 Blower Application

The Dayton 1TDT2 is a rectangle replacement OEM blower rated at 549 cfm at zero static pressure. It uses a forward-curved wheel and direct-drive design for high-temperature environments. The unit arrives fully assembled and ready for installation.

Suitable Uses and Limitations

This blower suits OEM replacements where a 6-1/4 inch wheel and direct-drive airflow are specified. It is not for installations that require a drive package or different wheel geometry. Buyers needing airflow ratings at intermediate static pressures not listed should look elsewhere.

Airflow at Static Pressure

At 0.000 in SP the blower delivers 549 cfm, dropping to 538 cfm at 0.100 in SP and 507 cfm at 0.250 in SP. Higher resistance points show 480 cfm at 0.400 in SP and 450 cfm at 0.500 in SP. This curve determines whether the part matches the system requirement.

Highlights

  • High airflow of 549 cfm at zero static pressure
  • Consistent output of 538 cfm at 0.100 in SP
  • Reliable delivery of 507 cfm at 0.250 in SP
  • Steady performance of 480 cfm at 0.400 in SP
  • Usable flow of 450 cfm at 0.500 in SP

Specifications

BrandDayton
typeHigh Temperature

Questions about this item

Does the Dayton 1TDT2 blower ship fully assembled or do I need to add a drive package?

The unit arrives assembled; the specifications list the drive package as not applicable, so no separate drive components are required.

The spec sheet shows several static-pressure points — which airflow figure should I use for sizing?

Use the 549 cfm at 0.000 in SP for free-air reference, then match your duct static pressure to the nearest listed point — 538 cfm at 0.100 in, 507 cfm at 0.250 in, 480 cfm at 0.400 in, or 450 cfm at 0.500 in.

What does the 549 cfm rating mean once the blower is installed in a real system?

It represents the maximum airflow at zero static pressure; actual delivery drops to 538 cfm at 0.100 in SP, 507 cfm at 0.250 in SP, 480 cfm at 0.400 in SP and 450 cfm at 0.500 in SP as duct resistance increases.