CyberPower
CyberPower PR3000RTXL2UACN UPS 3000VA/3000W 100-120V NEMA L5-30P 2U Rack/Tower 9 Outlets
Line-interactive UPS delivers 3000 VA sine-wave power with 9 outlets and 3.7 min runtime at full load
- Input Voltage Range75 - 149V
- Input Frequency50/60 Hz
- Input ConnectionNEMA L5-30P
- VA Rating3000 VA
- Watts3000 W
- Output Voltage100-120 VAC +/- 5%
- 3000 VA / 3000 W capacity supports high-density server racks
- Pure sine wave output protects sensitive equipment from power gaps
- 9 outlets including 8 × NEMA 5-20R and 1 × NEMA L5-30R
- 2U rack/tower convertible design fits standard enclosures
- 2430 joules surge protection guards connected hardware
Smart App Sinewave UPS 3000 VA
The PR3000RTXL2UACN is a line-interactive UPS that delivers 3000 VA and 3000 W of sine-wave output for servers and network gear. It accepts 75 to 149 V input at 50 or 60 Hz through a NEMA L5-30P plug with a 10 ft cord. The 2U rack-tower chassis fits standard racks or sits on a shelf.
Suits IT managers protecting critical loads
This unit serves environments that require pure sine-wave power for active PFC power supplies and sensitive electronics. Nine outlets — eight NEMA 5-20R and one NEMA L5-30R — provide battery-backed and surge-protected connections. Buyers needing longer autonomy at full load or a different input voltage range should evaluate other topologies.
Runtime at full load is 3.7 minutes
At 100 percent load the internal sealed lead-acid batteries run for 3.7 minutes; at half load the runtime extends to 11.7 minutes. Recharge to 90 percent takes 3 hours. The RB1260X8 battery pack is user-replaceable. Surge protection is rated at 2430 joules with circuit-breaker and internal circuitry limiting. Management interfaces include USB, serial, SNMP, relay, EPO and cloud via PowerPanel Business.
Highlights
- 3000 VA / 3000 W capacity supports high-density server racks
- Pure sine wave output protects sensitive equipment from power gaps
- 9 outlets including 8 × NEMA 5-20R and 1 × NEMA L5-30R
- 2U rack/tower convertible design fits standard enclosures
- 2430 joules surge protection guards connected hardware
Specifications
| Brand | CyberPower |
|---|---|
| Model | PR3000RTXL2UACN |
| Input Voltage Range | 75 - 149V |
| Input Frequency | 50/60 Hz |
| Input Connection | NEMA L5-30P |
| VA Rating | 3000 VA |
| Watts | 3000 W |
| Output Voltage | 100-120 VAC +/- 5% |
| Outlets | 9 |
| Outlet Type | 8 x NEMA 5-20R 1 - NEMA L5-30R |
| Battery Type | Sealed Lead Acid |
| Battery Run Time | 3.7 min at Full Load / 11.7 min at Half Load |
| Battery Recharge Time | 3 Hours (0% to 90% charged) |
| Battery Replaceable | RB1260X8 |
| Alarms | Battery Mode Low Battery Overload Overcharge Overheat |
| Interface Port | USB, Serial, SNMP, Relay, EPO, Cloud |
| Management Software | PowerPanel Business |
| Rackmountable | Yes |
| Surge Energy Rating | 2430 Joules |
| Protection | Internal Circuitry Limiting Circuit Breaker Protected |
| Dimensions | 17.1'' x 3.4'' x 24.8'' (W x H x D) |
| Weight | 88.4 lbs. |
| Shipping weight | 43.55 kg |
| Package size | 762 × 559 × 254 mm |
Questions about this item
How often will the RB1260X8 battery pack need replacement under normal use?
The sealed lead-acid RB1260X8 pack is user-replaceable and typically lasts three to five years; recharge from empty to 90 % takes three hours.
What runtime limit appears first when the UPS runs at full 3000 W load?
At full load the battery provides 3.7 minutes of sine-wave output before low-battery alarm triggers shutdown.
How much heat and fan noise should I expect from the 2U rack unit running continuously?
Line-interactive topology keeps fans off during normal utility operation; they engage only on battery or over-temperature, so idle heat and noise stay minimal.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.