We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

CyberPower

CyberPower PR3000RTXL2UACN UPS 3000VA/3000W 100-120V NEMA L5-30P 2U Rack/Tower 9 Outlets

SKU CH-J9NJ-S3E9V MPN PR3000RTXL2UACN

Line-interactive UPS delivers 3000 VA sine-wave power with 9 outlets and 3.7 min runtime at full load

  • Input Voltage Range75 - 149V
  • Input Frequency50/60 Hz
  • Input ConnectionNEMA L5-30P
  • VA Rating3000 VA
  • Watts3000 W
  • Output Voltage100-120 VAC +/- 5%
  • 3000 VA / 3000 W capacity supports high-density server racks
  • Pure sine wave output protects sensitive equipment from power gaps
  • 9 outlets including 8 × NEMA 5-20R and 1 × NEMA L5-30R
  • 2U rack/tower convertible design fits standard enclosures
  • 2430 joules surge protection guards connected hardware

Smart App Sinewave UPS 3000 VA

The PR3000RTXL2UACN is a line-interactive UPS that delivers 3000 VA and 3000 W of sine-wave output for servers and network gear. It accepts 75 to 149 V input at 50 or 60 Hz through a NEMA L5-30P plug with a 10 ft cord. The 2U rack-tower chassis fits standard racks or sits on a shelf.

Suits IT managers protecting critical loads

This unit serves environments that require pure sine-wave power for active PFC power supplies and sensitive electronics. Nine outlets — eight NEMA 5-20R and one NEMA L5-30R — provide battery-backed and surge-protected connections. Buyers needing longer autonomy at full load or a different input voltage range should evaluate other topologies.

Runtime at full load is 3.7 minutes

At 100 percent load the internal sealed lead-acid batteries run for 3.7 minutes; at half load the runtime extends to 11.7 minutes. Recharge to 90 percent takes 3 hours. The RB1260X8 battery pack is user-replaceable. Surge protection is rated at 2430 joules with circuit-breaker and internal circuitry limiting. Management interfaces include USB, serial, SNMP, relay, EPO and cloud via PowerPanel Business.

Highlights

  • 3000 VA / 3000 W capacity supports high-density server racks
  • Pure sine wave output protects sensitive equipment from power gaps
  • 9 outlets including 8 × NEMA 5-20R and 1 × NEMA L5-30R
  • 2U rack/tower convertible design fits standard enclosures
  • 2430 joules surge protection guards connected hardware

Specifications

BrandCyberPower
ModelPR3000RTXL2UACN
Input Voltage Range75 - 149V
Input Frequency50/60 Hz
Input ConnectionNEMA L5-30P
VA Rating3000 VA
Watts3000 W
Output Voltage100-120 VAC +/- 5%
Outlets9
Outlet Type8 x NEMA 5-20R
1 - NEMA L5-30R
Battery TypeSealed Lead Acid
Battery Run Time3.7 min at Full Load / 11.7 min at Half Load
Battery Recharge Time3 Hours (0% to 90% charged)
Battery ReplaceableRB1260X8
AlarmsBattery Mode
Low Battery
Overload
Overcharge
Overheat
Interface PortUSB, Serial, SNMP, Relay, EPO, Cloud
Management SoftwarePowerPanel Business
RackmountableYes
Surge Energy Rating2430 Joules
ProtectionInternal Circuitry Limiting
Circuit Breaker Protected
Dimensions17.1'' x 3.4'' x 24.8'' (W x H x D)
Weight88.4 lbs.
Shipping weight43.55 kg
Package size762 × 559 × 254 mm

Questions about this item

How often will the RB1260X8 battery pack need replacement under normal use?

The sealed lead-acid RB1260X8 pack is user-replaceable and typically lasts three to five years; recharge from empty to 90 % takes three hours.

What runtime limit appears first when the UPS runs at full 3000 W load?

At full load the battery provides 3.7 minutes of sine-wave output before low-battery alarm triggers shutdown.

How much heat and fan noise should I expect from the 2U rack unit running continuously?

Line-interactive topology keeps fans off during normal utility operation; they engage only on battery or over-temperature, so idle heat and noise stay minimal.

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.