CyberPower
CyberPower PDU83105 3-Phase 200-240V 30A Switched Metered-by-Outlet PDU 30 Outlets 10ft NEMA L15-30P 0U LCD
Three-phase switched PDU with 30 IEC-320 outlets, metered-by-outlet monitoring, 10 ft cord and NEMA L15-30P input
- TypeBasic
- Metered-by-outlet monitoring tracks real-time power use per outlet
- Individual outlet switching enables remote reboot and load shedding
- 3-phase 200-240V input with 30A derated capacity supports dense racks
- 30 IEC outlets (24 C13 + 6 C19) fit varied equipment
- 0U vertical 10ft cord NEMA L15-30P saves rack space
Data-centre power distribution
The CyberPower PDU83105 is a 3-phase switched metered-by-outlet PDU rated for 200-240V and 30A input. It suits data centres and network closets that need real-time outlet-level monitoring and remote reboot capability for connected servers and networking gear.
Vertical 0U mounting and LCD
The unit mounts vertically in a 0U form factor with a 10ft cord ending in a NEMA L15-30P plug. An interactive digital display with selectable background colour shows live readings, while multi-colour outlet LEDs give instant visual status without opening the cabinet door.
Check phase voltage and outlet mix
Verify your facility supplies 3-phase 200-240V at 50/60Hz and that the NEMA L15-30P plug matches your source receptacle. Ensure the 24 C13 and 6 C19 outlets match the IEC-320 plugs on your equipment before ordering.
Highlights
- Metered-by-outlet monitoring tracks real-time power use per outlet
- Individual outlet switching enables remote reboot and load shedding
- 3-phase 200-240V input with 30A derated capacity supports dense racks
- 30 IEC outlets (24 C13 + 6 C19) fit varied equipment
- 0U vertical 10ft cord NEMA L15-30P saves rack space
Specifications
| Brand | CyberPower |
|---|---|
| Type | Basic |
| Shipping weight | 11.34 kg |
| Package size | 2060 × 175 × 155 mm |
Questions about this item
How can I confirm the PDU83105 is monitoring each outlet correctly after installation?
The interactive digital display shows real-time metered-by-outlet readings for all 30 outlets, and the built-in web interface provides remote access to the same per-outlet power data.
Which cords or mounting hardware are included with the PDU83105 and what must I source separately?
The unit ships with a 10 ft input cord ending in a NEMA L15-30P plug and vertical 0U mounting brackets; you must supply IEC-320 C13 and C19 cables to connect your equipment to the 24 C13 and 6 C19 outlets.
Should I choose a different outlet mix or phase configuration for my 200-240V 30A rack?
This model is fixed at 3-phase 200-240V with 24 C13 and 6 C19 outlets; if your devices need a different receptacle count or single-phase input, another PDU variant would be required.