CyberPower PDU83104 3-Phase Switched PDU 30A 200-240V 30 IEC-320 Outlets
A 3-phase switched PDU delivering outlet-level monitoring and remote control across 30 IEC-320 outlets at 30A 200-240V
- TypeOthers
- Outlet-level power monitoring in real time
- Individual outlet control enables remote reboot and load shedding
- 30 IEC-320 outlets for high-density deployments
- 200-240V three-phase input suits data-centre racks
- Ultra-low self-consumption reduces operating cost
3-Phase Switched PDU with 30 Outlets
The CyberPower PDU83104 is a 3-phase switched power distribution unit rated for 30A at 200-240V. It delivers 30 IEC-320 outlets for dense rack deployments in data centres and network closets. Outlet-level metering and remote switching give administrators real-time visibility and control over every connected device.
Upgrade from basic or metered-only PDUs
This unit replaces unmonitored or aggregate-metered strips when you need per-outlet power data and remote reboot capability. The jump is worth it when capacity planning requires granular consumption records or when technicians must power-cycle individual servers without visiting the rack. Switched metered-by-outlet functionality supports load-shedding and sequenced start-up scenarios.
Verify rack power and outlet compatibility
Confirm the facility provides a 3-phase 200-240V 30A feed that matches the unit's input specification. Ensure the 30 IEC-320 outlets suit the plug types on your equipment and that the rack depth accommodates the PDU chassis. Check that network management tools can integrate with the built-in web interface for monitoring and alerting.
Highlights
- Outlet-level power monitoring in real time
- Individual outlet control enables remote reboot and load shedding
- 30 IEC-320 outlets for high-density deployments
- 200-240V three-phase input suits data-centre racks
- Ultra-low self-consumption reduces operating cost
Specifications
| Brand | CyberPower |
|---|---|
| Type | Others |
| Shipping weight | 11.34 kg |
| Package size | 2060 × 175 × 155 mm |
Questions about this item
What rack space and input connection does the PDU83104 require?
The unit mounts in a standard rack and accepts a 3-phase 30 A feed at 200-240 V.
How is the PDU83104 configured for remote outlet control, and what step is often missed?
Connect the network cable, set a static IP on the built-in web interface, then enable SNMP or API access; skipping the IP assignment leaves the PDU unreachable.
Which parts of the PDU83104 will need attention or replacement over time?
The IEC-320 outlet modules and internal metering sensors are the serviceable items; the digital display and LED indicators are rated for the unit's full service life.