We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

CyberPower

CyberPower PDU44006 Switched ATS PDU 1U 10 Outlets 2x L6-20P 8x C13 2x C19

SKU CH-6P6F-0S7SK MPN PDU44006

Switched ATS PDU with dual L6-20P inputs and ten outlets — eight C13 and two C19 — for 200-240 V rack power redundancy

  • TypeSwitched
  • Rack Size1U
  • StyleRackmount
  • Remote Management ProtocolIPv4, TCP/IP, UDP, SNMPv1, HTTP, NTP, DNS, Telnet, DHCP, SMT
  • Front Panel LEDsSource Status Source Selected Output Normal/Warning/Critical
  • CertificationsEnvironmental RoHS Compliant Safety UL62368 FCC Class A cTUV
  • Switched ATS provides automatic failover between two 200–240 VAC sources
  • 1U rackmount form factor fits standard cabinets with 10 ft input cords
  • 10 locking outlets (8 C13, 2 C19) support diverse server and network gear
  • Remote management via Ethernet and serial using IPv4, IPv6, SNMPv3, SSH, TLS and more
  • Front-panel LEDs show source status, selected source, output state and network link health

Switched ATS PDU 1U

The CyberPower PDU44006 is a switched automatic-transfer-switch power distribution unit that fits a single rack unit. It delivers ten outlets — eight IEC-320 C13 and two IEC-320 C19 — from dual NEMA L6-20P inputs. Network and serial ports give administrators remote control over every outlet and power source.

Upgrade from basic PDU

A basic PDU only distributes power; this unit adds automatic source switching and per-outlet switching over IP. The jump is worth it when you need redundant 200-240 VAC feeds and the ability to reboot individual devices without visiting the rack.

Sustained-load behaviour

The regulatory derated input current is 16 A continuous across the 200-240 VAC range. Front-panel LEDs show source status, selected source, output state and normal/warning/critical thresholds in real time. Operating temperature spans 0-45 °C with humidity up to 95 % non-condensing.

Highlights

  • Switched ATS provides automatic failover between two 200–240 VAC sources
  • 1U rackmount form factor fits standard cabinets with 10 ft input cords
  • 10 locking outlets (8 C13, 2 C19) support diverse server and network gear
  • Remote management via Ethernet and serial using IPv4, IPv6, SNMPv3, SSH, TLS and more
  • Front-panel LEDs show source status, selected source, output state and network link health

Specifications

BrandCyberPower
SeriesSwitched ATS PDU Series
ModelPDU44006
Part NumberPDU44006
TypeSwitched
Rack Size1U
StyleRackmount
Remote Management ProtocolIPv4, TCP/IP, UDP, SNMPv1, HTTP, NTP, DNS, Telnet, DHCP, SMTP, FTP, IPv6, SNMPv3, HTTPs, SSH, SSL, TLS, LDAP(S), RADIUS, Syslog, CLI, Windows AD
Front Panel LEDsSource Status
Source Selected
Output
Normal/Warning/Critical Status
Tx/Rx
LINK
Outlets
CertificationsEnvironmental
RoHS Compliant
Safety
UL62368
FCC Class A
cTUVus
ROHSYes
ConnectivityEthernet (RJ45)
Serial (RJ45)
Input Voltage240 – 200 VAC
Input Frequency50 Hz – 60 Hz
Maximum Input Current20A
Regulatory Derated Input Current16 A
Input Connector(s)2 x NEMA L6-20P
Cord Length10 ft (3.0 m)
Output Voltage240 – 200 VAC
Output Connector(s)8 – IEC-320 C13
2 – IEC-320 C19
Operating Environment32 – 113 °F (0 – 45 °C)
Operating Relative Humidity0 – 95 % (non-condensing)
Operating Elevation0 – 13123 ft (0 – 4000 m)
Storage Temperature5 – 131 °F (-15 – 55 °C)
Storage Elevation0 – 49213 ft (0 – 14999 m)
Dimensions17.05 x 1.75 x 8.45 (in)
Weight8.3 (lb)
Shipping weight6.58 kg
Package size550 × 398 × 124 mm

Questions about this item

What rack depth and clearance does the 1U PDU44006 need for its two 10 ft L6-20P input cords?

The unit occupies 1U of rack height; allow enough depth behind the rails for the 3.0 m cords to bend without sharp kinks and keep the rear vents clear for 0 – 45 °C airflow.

Which management protocol must be enabled first so the switched outlets respond to SNMPv3 commands?

Connect the RJ45 Ethernet port, assign a static IPv4 or DHCP address via the web UI, then enable SNMPv3 and create the user credentials before the C13 and C19 outlets will accept remote on/off cycles.

At what ambient temperature should the internal components be inspected for dust buildup on the PDU44006?

Inspect the inlet and outlet grilles every 6 – 12 months when operating near the 45 °C upper limit; clean with low-pressure air to maintain the 16 A derated capacity and UL62368 safety compliance.

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.