CyberPower
CyberPower PDU44006 Switched ATS PDU 1U 10 Outlets 2x L6-20P 8x C13 2x C19
Switched ATS PDU with dual L6-20P inputs and ten outlets — eight C13 and two C19 — for 200-240 V rack power redundancy
- TypeSwitched
- Rack Size1U
- StyleRackmount
- Remote Management ProtocolIPv4, TCP/IP, UDP, SNMPv1, HTTP, NTP, DNS, Telnet, DHCP, SMT
- Front Panel LEDsSource Status Source Selected Output Normal/Warning/Critical
- CertificationsEnvironmental RoHS Compliant Safety UL62368 FCC Class A cTUV
- Switched ATS provides automatic failover between two 200–240 VAC sources
- 1U rackmount form factor fits standard cabinets with 10 ft input cords
- 10 locking outlets (8 C13, 2 C19) support diverse server and network gear
- Remote management via Ethernet and serial using IPv4, IPv6, SNMPv3, SSH, TLS and more
- Front-panel LEDs show source status, selected source, output state and network link health
Switched ATS PDU 1U
The CyberPower PDU44006 is a switched automatic-transfer-switch power distribution unit that fits a single rack unit. It delivers ten outlets — eight IEC-320 C13 and two IEC-320 C19 — from dual NEMA L6-20P inputs. Network and serial ports give administrators remote control over every outlet and power source.
Upgrade from basic PDU
A basic PDU only distributes power; this unit adds automatic source switching and per-outlet switching over IP. The jump is worth it when you need redundant 200-240 VAC feeds and the ability to reboot individual devices without visiting the rack.
Sustained-load behaviour
The regulatory derated input current is 16 A continuous across the 200-240 VAC range. Front-panel LEDs show source status, selected source, output state and normal/warning/critical thresholds in real time. Operating temperature spans 0-45 °C with humidity up to 95 % non-condensing.
Highlights
- Switched ATS provides automatic failover between two 200–240 VAC sources
- 1U rackmount form factor fits standard cabinets with 10 ft input cords
- 10 locking outlets (8 C13, 2 C19) support diverse server and network gear
- Remote management via Ethernet and serial using IPv4, IPv6, SNMPv3, SSH, TLS and more
- Front-panel LEDs show source status, selected source, output state and network link health
Specifications
| Brand | CyberPower |
|---|---|
| Series | Switched ATS PDU Series |
| Model | PDU44006 |
| Part Number | PDU44006 |
| Type | Switched |
| Rack Size | 1U |
| Style | Rackmount |
| Remote Management Protocol | IPv4, TCP/IP, UDP, SNMPv1, HTTP, NTP, DNS, Telnet, DHCP, SMTP, FTP, IPv6, SNMPv3, HTTPs, SSH, SSL, TLS, LDAP(S), RADIUS, Syslog, CLI, Windows AD |
| Front Panel LEDs | Source Status Source Selected Output Normal/Warning/Critical Status Tx/Rx LINK Outlets |
| Certifications | Environmental RoHS Compliant Safety UL62368 FCC Class A cTUVus |
| ROHS | Yes |
| Connectivity | Ethernet (RJ45) Serial (RJ45) |
| Input Voltage | 240 – 200 VAC |
| Input Frequency | 50 Hz – 60 Hz |
| Maximum Input Current | 20A |
| Regulatory Derated Input Current | 16 A |
| Input Connector(s) | 2 x NEMA L6-20P |
| Cord Length | 10 ft (3.0 m) |
| Output Voltage | 240 – 200 VAC |
| Output Connector(s) | 8 – IEC-320 C13 2 – IEC-320 C19 |
| Operating Environment | 32 – 113 °F (0 – 45 °C) |
| Operating Relative Humidity | 0 – 95 % (non-condensing) |
| Operating Elevation | 0 – 13123 ft (0 – 4000 m) |
| Storage Temperature | 5 – 131 °F (-15 – 55 °C) |
| Storage Elevation | 0 – 49213 ft (0 – 14999 m) |
| Dimensions | 17.05 x 1.75 x 8.45 (in) |
| Weight | 8.3 (lb) |
| Shipping weight | 6.58 kg |
| Package size | 550 × 398 × 124 mm |
Questions about this item
What rack depth and clearance does the 1U PDU44006 need for its two 10 ft L6-20P input cords?
The unit occupies 1U of rack height; allow enough depth behind the rails for the 3.0 m cords to bend without sharp kinks and keep the rear vents clear for 0 – 45 °C airflow.
Which management protocol must be enabled first so the switched outlets respond to SNMPv3 commands?
Connect the RJ45 Ethernet port, assign a static IPv4 or DHCP address via the web UI, then enable SNMPv3 and create the user credentials before the C13 and C19 outlets will accept remote on/off cycles.
At what ambient temperature should the internal components be inspected for dust buildup on the PDU44006?
Inspect the inlet and outlet grilles every 6 – 12 months when operating near the 45 °C upper limit; clean with low-pressure air to maintain the 16 A derated capacity and UL62368 safety compliance.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.