We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

CyberPower

CyberPower PDU42014 Switched PDU 100-240 VAC 20 A 10 ft IEC-320 C20 SNMP

SKU CH-TDFG-DN844 MPN PDU42014

Distributes 100-240 VAC power with switched outlet control, 20 A rating, 10 ft cord, IEC-320 C20 input and SNMP monitoring

  • Switched outlets enable remote power cycling via SNMP
  • 10 ft cord provides flexible rack placement with straight C20 plug
  • 20 A rating supports high-density equipment loads
  • Single-phase 100-240 VAC input works worldwide without configuration
  • Derated 16 A input ensures safe continuous operation on standard circuits

Single-phase switched PDU

The CyberPower PDU42014 is a single-phase power distribution unit rated for 100-240 VAC input at 50-60 Hz. It delivers up to 20 A through an IEC-320 C20 inlet with a 10 ft cord. Network management via SNMP allows remote outlet control and monitoring for rack-mounted equipment.

Upgrade from basic power strips

This unit replaces unmanaged power strips when administrators need per-outlet switching and remote reboot capability. The jump is worth it when uptime depends on cycling power to individual servers or network gear without physical access to the rack. Derated input of 16 A provides a safety margin for continuous loads.

IEC-320 C20 inlet constraint

The fixed C20 inlet limits connection to compatible UPS outputs or wall receptacles rated for 20 A. Installations requiring a different plug style or higher current capacity cannot use this unit without an adapter that may void certification. The 10 ft cord length also restricts placement relative to the power source.

Highlights

  • Switched outlets enable remote power cycling via SNMP
  • 10 ft cord provides flexible rack placement with straight C20 plug
  • 20 A rating supports high-density equipment loads
  • Single-phase 100-240 VAC input works worldwide without configuration
  • Derated 16 A input ensures safe continuous operation on standard circuits

Specifications

No published specifications for this item yet.

Questions about this item

What input plug and voltage range does the PDU42014 need to connect to?

The PDU42014 uses an IEC-320 C20 input plug and accepts 100-240 VAC single-phase power at 50-60 Hz.

How do you set up network management on the PDU42014, and what step is often missed?

Connect the unit to your network, then configure the SNMP settings in the web interface; the step often missed is enabling SNMP traps for alert notifications.

When will the PDU42014 need its input cord or plug replaced?

Replace the 10 ft IEC-320 C20 cord if the plug shows heat damage, the cable jacket cracks, or the unit trips its 20 A breaker repeatedly under normal 16 A derated loads.

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.