We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

CyberPower

CyberPower PDU33103 PDU 3-Phase 120/208V 20A 44 Outlets NEMA L21-20P 0U LCD

SKU CH-W6HW-00JT3 MPN PDU33103

Three-phase monitored power distribution unit delivers 120/208 V at 20 A through 44 mixed outlets in a 0U vertical form factor with LCD readout

  • 3-phase 120/208V power feeds dense racks efficiently
  • 44 mixed outlets support diverse server plugs directly
  • 0U vertical design preserves rack space for gear
  • LCD metering shows live load per phase instantly
  • Email, SMS and SNMP traps alert on thresholds

Three-Phase Monitored PDU

The CyberPower PDU33103 is a three-phase monitored power distribution unit built for data-centre racks and server rooms. It accepts a 120/208 VAC 20 A feed through a NEMA L21-20P plug and distributes it across 44 outlets in a 0U vertical form factor. An integrated LCD provides local metering while email, SMS text and SNMP trap notifications alert administrators to power events. This unit suits operators who need per-outlet awareness on a three-phase circuit.

Derated 16 A Input and Outlet Mix

The 20 A input is derated to 16 A continuous per electrical code, so total connected load must stay within that limit. The outlet array comprises two NEMA 5-20R, thirty-six IEC-320 C13 and six IEC-320 C19 receptacles, giving a fixed mix of North American and IEC connectors. The 10 ft input cord sets the maximum reach from the branch circuit. Builds requiring a different plug type, single-phase supply or a higher continuous ampacity cannot use this PDU.

Forty-Four Outlets with C13 and C19 Headroom

With thirty-six C13 and six C19 outlets the PDU comfortably powers dense 1U and 2U servers, network switches and storage arrays that use standard IEC cords. The two 5-20R outlets handle occasional North American plug devices without adapters. Once all forty-four outlets are populated or the 16 A derated limit is reached, no further devices can be added. Racks needing more than six high-current C19 connections or a different outlet ratio will require an additional distribution unit.

Highlights

  • 3-phase 120/208V power feeds dense racks efficiently
  • 44 mixed outlets support diverse server plugs directly
  • 0U vertical design preserves rack space for gear
  • LCD metering shows live load per phase instantly
  • Email, SMS and SNMP traps alert on thresholds

Specifications

No published specifications for this item yet.

Questions about this item

Which outlet mix should I choose between the NEMA 5-20R, IEC C13 and IEC C19 sockets?

This unit provides two NEMA 5-20R, thirty-six IEC-320 C13 and six IEC-320 C19 outlets, giving 44 sockets total for mixed 120 V and 208 V equipment.

What does the 20 A rating mean once the PDU is installed in a rack?

The input is rated 20 A but derated to 16 A continuous, so plan loads that stay within 16 A per phase on the 120/208 V three-phase supply.

What does the NEMA L21-20P plug cap in practice?

The NEMA L21-20P plug connects to a 20 A three-phase 120/208 V source and locks in place, limiting total input current to the 16 A derated value.

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.