CyberPower
CyberPower PDU24006 Metered ATS PDU 1U Rackmount 2x NEMA L6-20P 8x C13 2x C19
Metered ATS PDU distributes 200–240 VAC power through eight C13 and two C19 outlets with dual NEMA L6-20P inputs and selectable LCD monitoring
- TypeMetered
- Rack Size1U
- StyleRackmount
- Input Voltage240 – 200 VAC
- Input Frequency50 Hz – 60 Hz
- Maximum Input Current20A
- Automatic transfer switching ensures continuous power redundancy
- Metered LCD display provides real-time load monitoring
- Dual NEMA L6-20P inputs enable redundant power feeds
- Ten C13 and C19 outlets support mixed-density rack gear
- One-U metal chassis fits standard 19-inch racks
1U Metered ATS Rackmount PDU
The CyberPower PDU24006 is a 1U rackmount power distribution unit with an automatic transfer switch and a selectable colour LCD meter. It accepts dual 200–240 VAC inputs through two NEMA L6-20P plugs on a 10 ft cord. Eight IEC-320 C13 and two IEC-320 C19 outlets deliver the same voltage to connected equipment. The metal housing includes all mounting hardware for standard racks.
Dual-Source Redundancy For Single-Cord Devices
This unit suits racks where servers or network gear have only one power supply but the site provides two independent feeds. The automatic transfer switch moves the load to the secondary source within milliseconds if the primary fails. It is not for installations that require local overload protection on each outlet branch. Facilities needing per-outlet circuit breakers or metered switching should consider a different PDU topology.
20 A Maximum Input Current
The PDU is rated for a maximum input current of 20 A across both NEMA L6-20P inlets. This single figure governs the total connected load and determines whether the unit can support a given rack population. Exceeding 20 A will trip the upstream supply, so the buyer must sum device draw before deployment.
Highlights
- Automatic transfer switching ensures continuous power redundancy
- Metered LCD display provides real-time load monitoring
- Dual NEMA L6-20P inputs enable redundant power feeds
- Ten C13 and C19 outlets support mixed-density rack gear
- One-U metal chassis fits standard 19-inch racks
Specifications
| Brand | CyberPower |
|---|---|
| Series | Metered ATS PDU |
| Model | PDU24006 |
| Part Number | PDU24006 |
| Type | Metered |
| Rack Size | 1U |
| Style | Rackmount |
| Input Voltage | 240 – 200 VAC |
| Input Frequency | 50 Hz – 60 Hz |
| Maximum Input Current | 20A |
| Input Connector(s) | Straight (Socket) 2 x NEMA L6-20P |
| Cord Length | 10 ft (3.0 m) |
| Output Voltage | 240 – 200 VAC |
| Output Connector(s) | 8 – IEC-320 C13 2 – IEC-320 C19 |
| Overload Protection | None |
| Operating Environment | 32 – 113 °F (0 – 45 °C) |
| Operating Relative Humidity | 0 – 95 % (non-condensing) |
| Operating Elevation | 0 – 13123 ft (0 – 4000 m) |
| Storage Temperature | 5 – 131 °F (-15 – 55 °C) |
| Storage Elevation | 0 – 49213 ft (0 – 14999 m) |
| Dimensions | 17.05 x 1.75 x 8.45 (in) |
| Weight | 11 LB |
| Shipping weight | 6.35 kg |
| Package size | 550 × 398 × 124 mm |
Questions about this item
How can I confirm the automatic transfer switch is functioning after rack-mounting the PDU24006?
The selectable colour LCD on the front panel shows real-time input-source status and load current so you can verify the ATS switches between the two NEMA L6-20P feeds without interruption.
What ships with the PDU24006 and which cables must I source separately?
The unit includes all 1U rack-mounting hardware and a 10 ft input cord ending in 2 x NEMA L6-20P plugs; you must supply IEC C13 or C19 power cords to connect your servers to the 8 x C13 and 2 x C19 outlets.
Which capacity should I choose if my rack draws up to 20 A at 200–240 VAC?
The PDU24006 is rated for a maximum input current of 20 A, so it matches a 20 A circuit; select this model when your combined load stays within that 20 A limit.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.