CyberPower PDU24002 Metered ATS PDU 20A 100-120V 10 Outlets 1U LCD
A metered automatic-transfer PDU with ten NEMA 5-20R outlets, dual NEMA L5-20P inputs, LCD monitoring and a 1U horizontal form factor
- TypeSwitched
- Metered power monitoring tracks real-time load
- Automatic transfer switching provides redundant power paths
- Ten NEMA 5-20R outlets support multiple devices
- Dual NEMA L5-20P inputs enable dual-source feeds
- LCD display shows voltage, current and status
Metered ATS PDU with dual input
The CyberPower PDU24002 is a metered automatic transfer switch power distribution unit built for single-phase 100 to 120 VAC environments. It supplies ten NEMA 5-20R outlets from dual NEMA L5-20P inputs and fits a 1U horizontal rack space. An integrated LCD provides real-time load data for each connected device.
Suited for dual-corded rack gear
This unit serves administrators who need redundant power for equipment with two power supplies in a 20 A, 100 to 120 V rack. It is not intended for three-phase installations, higher-voltage feeds or sites that require more than ten outlets per PDU.
Continuous metering under load
The LCD reports aggregate current draw continuously, letting operators track sustained consumption rather than brief peaks. Automatic transfer between the two sources occurs without interruption, maintaining power to attached servers during source fluctuations.
Highlights
- Metered power monitoring tracks real-time load
- Automatic transfer switching provides redundant power paths
- Ten NEMA 5-20R outlets support multiple devices
- Dual NEMA L5-20P inputs enable dual-source feeds
- LCD display shows voltage, current and status
Specifications
| Brand | CyberPower |
|---|---|
| Type | Switched |
| Shipping weight | 0.05 kg |
| Package size | 550 × 400 × 125 mm |
Questions about this item
What input connection does the PDU24002 need on each power source?
Each power source must provide a NEMA L5-20P locking plug rated for 20 A at 100-120 VAC single phase.
Will the ten NEMA 5-20R outlets accept standard 5-15P equipment plugs?
Yes, the 5-20R receptacles accept both 5-20P and 5-15P plugs, so existing 15 A devices can be used without adapters.
How can I confirm the ATS is switching cleanly after installation?
The front LCD shows real-time voltage, current and active source for each input, and the LED status indicator displays the current operating state.