CyberPower PDU15M2F8R Metered 1U 10-Outlet PDU 120V 15A 15ft Cord
A 1U metered power distribution unit supplies 120 V 15 A through ten NEMA 5-15R outlets from a single NEMA 5-15P plug with a 15 ft cord
- TypeMetered
- Rack Size1U
- Input Voltage120V
- Input Frequency60 Hz
- Maximum Input Current15 A
- Input Connector(s)NEMA 5-15P
- Metered display tracks real-time load on 10 outlets
- 1U rack height fits standard enclosures
- 15 A capacity supports dense equipment deployments
- 15 ft input cord reaches distant power sources
- 62 lb weight simplifies single-person installation
Metered 1U PDU with 10 NEMA 5-15R outlets
This metered power distribution unit fits a standard 1U rack space and delivers 120V output to ten NEMA 5-15R receptacles. It is built for server rooms and network closets that need basic power distribution with local current monitoring. The unit weighs 5.62 units and connects through a single NEMA 5-15P plug.
15 A maximum input current at 120V
The PDU accepts a maximum input current of 15 A at 120V and 60 Hz, which sets the total load limit for all connected equipment. A 15 ft input cord with a NEMA 5-15P plug links the unit to the upstream power source. Exceeding the 15 A rating will trip the supply breaker.
Passive thermal design with unfiltered pass-through
The unit uses unfiltered electrical pass-through and has no active cooling components, so it adds no fan noise to the rack environment. Heat dissipation relies on natural convection through the metal chassis during normal operation. Power draw is limited to the attached loads up to the 15 A rating.
Highlights
- Metered display tracks real-time load on 10 outlets
- 1U rack height fits standard enclosures
- 15 A capacity supports dense equipment deployments
- 15 ft input cord reaches distant power sources
- 62 lb weight simplifies single-person installation
Specifications
| Brand | CyberPower |
|---|---|
| Model | PDU15M2F8R |
| Type | Metered |
| Rack Size | 1U |
| Input Voltage | 120V |
| Input Frequency | 60 Hz |
| Maximum Input Current | 15 A |
| Input Connector(s) | NEMA 5-15P |
| Cord Length | 15 ft. |
| Output Voltage | 120V |
| Output Frequency | 60 Hz |
| Output Connector(s) | 10 x NEMA 5-15R |
| Features | The CyberPower Metered PDU15M2F8R 10-Outlets PDU provides 120V 15A output. It distributes power to 10 NEMA 5-15R receptacles from a single NEMA 5-15P plug, with unfiltered electrical pass-through. The current draw for connected equipment is displayed in amps on the front LCD for real-time load monitoring. Designed for datacenters and other electrically demanding applications, this unit has a rugged, industrial-grade metal housing and a 15-foot AC power cord. It can be mounted either horizontally or vertically, includes a cord retention tray and is ETL/RoHS certified. A lifetime warra |
| Weight | 5.62 |
| Shipping weight | 6.90 kg |
| Package size | 1778 × 56 × 44 mm |
Questions about this item
How does the 15 A metered rating affect what I can plug into the 10 outlets?
The meter shows total current draw across all 10 NEMA 5-15R receptacles so you can keep the combined load at or below 15 A and avoid tripping the input breaker.
What does the NEMA 5-15P input plug limit in a typical rack installation?
The NEMA 5-15P plug connects to a standard 120 V 15 A branch circuit, capping total PDU output at 15 A regardless of how many outlets are used.
What physical space and mounting does the 1U chassis need?
The unit occupies one rack unit of vertical space and mounts in a standard 1U opening; the 15 ft input cord routes from the rear.