Cooper Wiring
Cooper Wiring 877V-BOX Ivory Duplex Receptacle 20A 125V
Ivory duplex receptacle rated 20 A 125 V with triple-wipe contacts, galvanized strap and side-wire terminals for #10 wire
- Meets UL 498 safety standard for commercial installations
- Triple-wipe line contacts keep plugs secure over time
- Double-wipe ground contacts maintain reliable grounding
- Galvanised .50" steel strap resists corrosion in damp areas
- Side terminals accept up to #10 solid or stranded wire
Commercial-Grade Duplex Receptacle
The Cooper Wiring 877V-BOX is a 20-amp, 125-volt duplex receptacle built to commercial-grade specifications. It meets UL 498 requirements for safety and durability. The ivory finish suits standard residential or light-commercial décors. This unit is intended for side-wired installations using solid or stranded conductors up to #10 AWG.
Thermals Noise Power
The receptacle operates passively with no moving parts, so it produces no audible noise and draws no standby power. Its 0.50-inch thick galvanized steel mounting strap resists corrosion and helps dissipate normal operating heat. Triple-wipe line contacts and double-wipe ground contacts maintain low-resistance connections over long service life.
Installation Hardware Ready
Terminal screws are backed out from the factory, and the combination slot/Phillips heads accept common driver bits for faster wiring. An easy-access split-circuit break-off tab allows independent circuit control when required. The wrap-around mounting strap provides rigid alignment against the box without additional brackets.
Highlights
- Meets UL 498 safety standard for commercial installations
- Triple-wipe line contacts keep plugs secure over time
- Double-wipe ground contacts maintain reliable grounding
- Galvanised .50" steel strap resists corrosion in damp areas
- Side terminals accept up to #10 solid or stranded wire
Specifications
No published specifications for this item yet.
Questions about this item
How do I install the Cooper Wiring 877V-BOX duplex receptacle and what step is often missed?
Connect up to #10 solid or stranded wire to the side terminals; screws are backed out ready for wiring. The step often missed is breaking off the split-circuit tab when two separate circuits are needed.
What maintenance or replacement will this receptacle need over time?
The triple-wipe line contacts and double-wipe ground contacts are designed for long-term retention; no routine maintenance is required. Replace the unit if plug grip loosens or if the ivory face shows cracking or discoloration.
What is the first limit reached under sustained load on this 20 A 125 V receptacle?
The 20 A rating is the primary limit; continuous current must not exceed 20 amperes. The .50" galvanized steel strap and UL 498 construction handle the resulting heat, so ampacity is the limiting factor.