Cooper Atkins 35200-K thermometer, 1 in probe
NSF-certified thermocouple thermometer with ±0.5 °F accuracy, -100 °F to 999 °F range, 1-inch probe and backlit LCD
- TypeEnvironmental & Mechanical
- ±0.5 °F accuracy backed by NIST-traceable certificate
- Measures -100 °F to 999 °F with thermocouple probe
- 1/2 in backlit LCD shows 0.1 ° or 1 ° resolution
- Switchable °F/°C scales for flexible readouts
- Runs on two AAA batteries for portable operation
Professional temperature tool
The Cooper Atkins 35200-K is a thermocouple thermometer built for food-service and industrial environments where NSF compliance matters. A 1-inch probe reaches into product while the backlit LCD shows readings in 0.1 or 1 degree steps.
Battery powered simplicity
Two AAA cells run the unit with no mains wiring or external supply required. The display stays readable in low light and the thermocouple input accepts standard Type K sensors for a wide measurement span.
Replaces dial or glass thermometers
Teams moving from analog stem thermometers gain +/-0.5°F accuracy and a NIST-traceable certificate without changing workflow. The jump is worth it when audit trails demand documented calibration.
Highlights
- ±0.5 °F accuracy backed by NIST-traceable certificate
- Measures -100 °F to 999 °F with thermocouple probe
- 1/2 in backlit LCD shows 0.1 ° or 1 ° resolution
- Switchable °F/°C scales for flexible readouts
- Runs on two AAA batteries for portable operation
Specifications
| Brand | COOPER ATKINS |
|---|---|
| Type | Environmental & Mechanical |
Questions about this item
How do I install the two AAA batteries in the 35200-K thermometer, and what step do people often miss?
Open the battery compartment, insert two AAA cells matching the polarity markings, then close the cover fully so the seal seats; the step most users miss is pressing the cover until it clicks to maintain the NSF-rated splash resistance.
What maintenance will the 1-inch thermocouple probe need over time?
Wipe the probe tip with a damp cloth after each use and avoid submerging the handle; recalibrate using the included NIST-traceable certificate whenever readings drift beyond the stated ±0.5 °F / ±0.3 °C accuracy.
At what temperature does the 35200-K hit its measurement limit first during sustained high-heat use?
The upper limit is 999 °F (537 °C); sustained exposure near that ceiling will trigger the display’s over-range indicator before any other constraint appears.