Cameron & Co
Cameron & Co DS-CS-BCM522MD 6.0V 5000mAh Ni-MH battery
A 6.0 V 5000 mAh Ni-MH battery powers BCI Mini-Torr Plus, 6004 and 9004 monitors and replaces part numbers 58522B1 and OM11509
- TypeHome Electronics Battery
- Compatible with Mini-Torr Plus and 6004 monitors
- Powers 9004 Patient Monitor and Capnocheck devices
- Replaces original part numbers 58522B1 and OM11509
- Delivers 6.0V 5000mAh Ni-MH capacity
- Measures 161.00 x 62.20 x 32.78 mm
Replacement Battery for BCI Medical Monitors
This Cameron & Co DS-CS-BCM522MD Ni-MH pack delivers 6.0 V and 5000 mAh capacity. It is built to power BCI Mini-Torr Plus, 6004 Blood Pressure Monitor, 9004 Patient Monitor, Capnocheck plus and related capnography units. The blue housing matches the original form factor for direct installation.
Upgrade from Depleted or Ageing Packs
The cell replaces BCI part numbers 58522B1 and OM11509 when runtime has fallen below clinical requirements. A swap is justified when the existing battery no longer holds a full 30.00 Wh charge or shows voltage sag under load. No firmware or hardware changes are needed for the listed devices.
Suited for Biomedical Technicians
This unit fits the exact models named in the compatibility list and nothing else. Buyers needing a different voltage, chemistry or connector layout should look at other SKUs. It is not intended for consumer electronics or non-medical equipment.
Highlights
- Compatible with Mini-Torr Plus and 6004 monitors
- Powers 9004 Patient Monitor and Capnocheck devices
- Replaces original part numbers 58522B1 and OM11509
- Delivers 6.0V 5000mAh Ni-MH capacity
- Measures 161.00 x 62.20 x 32.78 mm
Specifications
| Brand | Cameron Sino |
|---|---|
| Model | DS-CS-BCM522MD |
| Type | Home Electronics Battery |
Questions about this item
What are the physical dimensions of this 6.0V 5000mAh Ni-MH battery?
It measures 161.00 x 62.20 x 32.78 mm and weighs approximately 100 g, matching the original BCI form factor for the Mini-Torr Plus 6004 and 9004 monitors.
How do I install the DS-CS-BCM522MD battery in my BCI monitor, and what step is often missed?
Open the battery compartment, disconnect the old pack, connect the new pack's plug observing the correct polarity, then secure the latch; the step often missed is fully seating the connector before closing the door.
When will this 30.00 Wh Ni-MH pack need replacement under normal clinical use?
Capacity gradually declines with charge cycles; plan on replacing the pack when run-time no longer covers a full shift, typically after several hundred cycles.