CALBRITE
CALBRITE S62000CP00 2 in Rigid Conduit Coupling 316 SS
A 2-inch threaded coupling in 316 stainless steel joins rigid or intermediate metallic conduit to NEC and UL 6A standards
- TypeConduit & Raceways
- 316 stainless steel resists corrosion in harsh environments
- NPS threaded connection fits RMC and IMC conduit without adapters
- UL and cUL listed for code-compliant installations
- 38 in inside diameter matches 2 in trade size conduit
- Polished finish simplifies cleaning and inspection
316 Stainless Steel Rigid Coupling
The CALBRITE S62000CP00 is a threaded conduit coupling manufactured from 316 stainless steel for trade size 2 in rigid metallic conduit. It provides a secure, corrosion-resistant connection in electrical raceway systems requiring UL and NEC compliance.
Build integration and clearance
The coupling uses NPS threads to join two lengths of threaded RMC or IMC conduit, adding 2 3/16 in overall length and 2 23/32 in overall width to the run. Its 2.38 in inside diameter maintains full conduit capacity while the polished finish eases thread engagement during assembly.
Sustained environment performance
316 stainless steel construction resists chemical and atmospheric corrosion in harsh industrial or marine locations over long service periods. UL 6A listing and ANSI/NFPA 70 compliance confirm the fitting retains structural and grounding integrity under continuous thermal cycling and mechanical vibration.
Highlights
- 316 stainless steel resists corrosion in harsh environments
- NPS threaded connection fits RMC and IMC conduit without adapters
- UL and cUL listed for code-compliant installations
- 38 in inside diameter matches 2 in trade size conduit
- Polished finish simplifies cleaning and inspection
Specifications
| Brand | Calbrite |
|---|---|
| Type | Conduit & Raceways |
Questions about this item
What is the maximum sustained temperature this 316 stainless steel coupling can withstand before the material begins to degrade?
The 316 stainless steel construction resists corrosion and high temperatures typical in industrial electrical installations, maintaining structural integrity under continuous operation.
How much heat does the coupling generate when conducting full rated current through a 2-inch rigid conduit run all day?
As a passive mechanical fitting with no electrical resistance of its own, the coupling generates no measurable heat during normal current-carrying operation.
Which specific conduit types and thread standards must my existing installation use for this coupling to connect properly?
This coupling accepts threaded RMC or IMC conduit with NPS threads, trade size 2 in, and meets ANSI/NFPA 70, NEC, UL 6A and UL/CUL listing requirements.