Cable Leader
Cable Leader 4ft IEC C20 to C19 12 AWG 20A/250V Red Power Extension Cord
A 4 ft red extension cord with a C20 plug and C19 socket, built from 12 AWG SJT copper rated 20A at 250V for rack PDU and server power links
- ColorRed
- Length5 - 10 ft.
- Connector Number2
- Wire Gauge12 AWG
- Extends C20/C19 reach by four feet without adapters
- Heavy-duty 12 AWG copper rated 20A / 250V for rack loads
- UL Listed and CSA certified for data-centre safety
- Red SJT jacket simplifies circuit tracing in dense racks
- Lifetime US-based warranty covers replacement if it ever fails
C20 to C19 rack power extension
This four-foot red cord extends the reach between a C20 inlet on a PDU or UPS and the C19 plug of an existing server or switch cable. The heavy-duty 12 AWG copper conductors are rated for 20 A at 250 V, making it suitable for high-draw rack equipment rather than light desktop gear. UL Listed and CSA certified construction meets data-centre safety requirements. Builders needing a different connector format or a longer run will need a separate solution.
Thermals and power draw in normal use
The SJT jacket is rated to 105 C and 300 V, so the cable stays cool when carrying typical rack loads well below the 20 A limit. Grounded three-conductor wiring prevents floating chassis potentials in standard rack deployments. No active cooling or fan noise is involved because the assembly is entirely passive. Installers who require in-line current monitoring must add a separate metered device.
Behaviour under sustained load
At the full 20 A rating the 12 AWG conductors maintain voltage drop within specification for continuous operation in dense rack rows. The UL and CSA certifications (file E210037) confirm compliance for constant-duty cycles rather than brief peaks. Red colour coding simplifies phase tracing during long-term maintenance windows. Users planning loads above 20 A must select a larger-gauge alternative.
Highlights
- Extends C20/C19 reach by four feet without adapters
- Heavy-duty 12 AWG copper rated 20A / 250V for rack loads
- UL Listed and CSA certified for data-centre safety
- Red SJT jacket simplifies circuit tracing in dense racks
- Lifetime US-based warranty covers replacement if it ever fails
Specifications
| Brand | GENERIC |
|---|---|
| Color | Red |
| Length | 5 - 10 ft. |
| Connector Number | 2 |
| Wire Gauge | 12 AWG |
Questions about this item
How do I connect the C20-to-C19 cord and which end goes where?
Plug the male C20 into the PDU, UPS or power source, then insert your existing cord into the female C19 socket; the step often missed is confirming the C19 side is fully seated before powering on.
What maintenance or replacement will this cord need over time?
Inspect the red SJT jacket and both IEC 60320 connectors periodically for cuts, heat discolouration or loose pins; replace the cord if any conductor insulation is damaged or the C19 socket grip weakens.
What is the first limit I will hit under continuous 20 A load?
The 12 AWG copper conductors are rated 20 A / 250 V with a 105 °C cable temperature limit; sustained full-load operation will reach that thermal ceiling before the 300 V insulation rating becomes a factor.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.