We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Bussmann

Bussmann S506-1.6-R Glass Fuse 1.60A 250V 35A 5 PK

SKU CH-W948-Z0PYE

Glass time-delay fuse rated 1.60 A at 250 V AC with a 35 A interrupt rating, supplied in a pack of five

  • Time-delay operation protects against nuisance trips
  • 35 A interrupt rating at 250 V AC
  • Glass body, 20 mm × 5 mm cylindrical form
  • cURus, IMQ and MITI/JET recognised
  • Pack of five fuses for multiple circuits

Glass Fuse Pack for Low-Current Circuits

This five-pack supplies 1.60 A time-delay glass fuses rated for 250 V AC with a 35 A interrupt rating. They suit maintenance technicians and hobbyists protecting small appliances, control boards or generator accessory circuits where a cylindrical 20 mm by 5 mm fuse is specified. The cURus, IMQ and MITI/JET recognitions confirm compliance for North American and international equipment. Buyers needing higher amperage or a different body size should select another series.

Direct Replacements for Common Series

Each fuse cross-references Bussmann GDC and S506, Littelfuse 218 and Mersen GDG series, so the pack drops into existing HTB-compatible fuse blocks without hardware changes. The single-element, non-rejection design means installation is a simple push-in swap, reducing downtime during field service. No additional software, adapters or mounting hardware are included or required. Installers who need rejection-style or PCB-mount variants must source a different part number.

1.60 A Rating Defines Circuit Compatibility

The 1.60 ampere continuous rating is the critical figure that determines whether this fuse matches the protected circuit’s design current. Exceeding this value causes nuisance blows; undersizing it risks equipment damage before the fuse opens. The 35 A interrupt capacity at 250 V AC limits use to circuits where prospective short-circuit current stays below that level. Engineers specifying protection for higher fault currents must choose a fuse with a greater interrupt rating.

Highlights

  • Time-delay operation protects against nuisance trips
  • 35 A interrupt rating at 250 V AC
  • Glass body, 20 mm × 5 mm cylindrical form
  • cURus, IMQ and MITI/JET recognised
  • Pack of five fuses for multiple circuits

Specifications

BrandEATON BUSSMANN

Questions about this item

When will the S506-1.6-R glass fuse need replacement?

The fuse is a single-use protective device; it must be replaced after it interrupts a fault current of up to 35A at 250V AC.

What is the first limit reached during sustained operation?

The 1.60A continuous current rating is the limit; exceeding it will cause the time-delay element to open the circuit.

How much heat does the 20mm x 5mm glass fuse generate when running all day?

At the rated 1.60A the fuse operates within its design temperature rise; no additional cooling is required for the cylindrical glass body.

Also in this aisle