Bussmann
Bussmann PON40 40A 250VAC Time Delay Fiberglass Fuse
A 40 A time-delay fiberglass fuse rated 250 V AC with a 10 kA interrupt rating and 76.2 mm cylindrical body
- TypeEnclosures
- 40 A time-delay protection prevents nuisance tripping on motor starts
- 10 kA interrupt rating at 250 V AC safely clears heavy fault currents
- Dual-element construction handles overloads and short-circuits in one fuse
- CSA C 22.2 No. 59.1 listing confirms compliance with Canadian safety standards
- Fiberglass body resists heat and shattering in harsh electrical enclosures
Product Identity
The Bussmann PON40 is a cylindrical time-delay fuse rated at 40 amps and 250 volts AC. It uses a fiberglass body measuring 76.2 millimetres long by 20.6 millimetres in diameter. The fuse carries a 10 kiloamp interrupt rating at 250 volts AC and meets CE and CSA C22.2 No. 59.1 standards.
Suitable Applications
This fuse suits circuits that need a 40-amp time-delay device with a cylindrical fiberglass housing. Buyers who require a different current rating, a different voltage rating, a non-time-delay characteristic, or a rejection-style fuse should look at something else.
Decisive Specification
The 40-ampere 250-volt AC time-delay rating in a 76.2-by-20.6-millimetre cylindrical fiberglass body is the single specification that determines whether this fuse fits the application.
Highlights
- 40 A time-delay protection prevents nuisance tripping on motor starts
- 10 kA interrupt rating at 250 V AC safely clears heavy fault currents
- Dual-element construction handles overloads and short-circuits in one fuse
- CSA C 22.2 No. 59.1 listing confirms compliance with Canadian safety standards
- Fiberglass body resists heat and shattering in harsh electrical enclosures
Specifications
| Brand | BUSSMANN |
|---|---|
| Type | Enclosures |
Questions about this item
What fuse holder or disconnect accepts a 76.2 mm by 20.6 mm cylindrical fuse?
A holder rated for 250 V AC and 40 A with a 20.6 mm diameter bore and 76.2 mm clip spacing will accept this PON40 fuse.
Will the 10 kA interrupt rating protect my existing 250 V AC panel?
Yes, the 10 kA at 250 V AC rating meets or exceeds the short-circuit capability of standard 250 V AC panels.
How can I confirm the fuse has blown after installation?
Because this is a non-indicating fuse, use a multimeter to check for continuity across the fiberglass body after a suspected fault.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Thomas & Betts TY523M Cable Tie 18lb 4in Natural Nylon Stainless Steel Locking Clip Pack 100
CALBRITE S60700FDCC Weatherproof Electrical Box 5.90" x 2.83" 25 cu in
- Electrical Boxes &…
HOFFMAN A12P10G Interior Panel Steel 10.75in H 8.88in W 14 Gauge
- Electrical Boxes &…