We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Burndy

Burndy Two Conductor Lugs 2AWG 3.2In

SKU CH-87D3-QYKTG

Two-conductor mechanical lug accepts aluminium or copper wire up to 600 kcmil, rated 600 V and 194 °F

  • TypeCommercial
  • Handles two conductors for parallel runs
  • Rated 600 V for industrial power circuits
  • Aluminium body resists corrosion in harsh environments
  • Operates up to 194 °F for high-temp panels
  • Accepts 1/2 in stud for secure mounting

Burndy Two-Conductor Lugs 2 AWG

These Burndy lugs accept stranded copper conductors from 2 AWG up to 600 kcmil and terminate two wires in a single aluminium body rated for 600 V. They suit commercial electricians and panel builders who need a compact mechanical connector for heavy-gauge aluminium or copper cable runs.

Thermals noise and power draw

The aluminium body is rated to a maximum operating temperature of 194 °F and carries up to 600 V without active cooling. As a passive mechanical connector it generates no noise and draws no power during normal operation.

What the accessories change

The slotted head and single 0.53 in hole on 3.2 in centres allow direct bolt-down mounting without additional hardware. Tongue dimensions of 1.75 in length, 2.42 in width and 0.44 in thickness keep the footprint small inside crowded enclosures.

Highlights

  • Handles two conductors for parallel runs
  • Rated 600 V for industrial power circuits
  • Aluminium body resists corrosion in harsh environments
  • Operates up to 194 °F for high-temp panels
  • Accepts 1/2 in stud for secure mounting

Specifications

BrandBurndy
TypeCommercial

Questions about this item

How do I install the Burndy two-conductor lug on 2 AWG copper wire and what step is often missed?

Strip the conductor, insert both wires fully into the aluminium body, then torque the slotted head screw to the manufacturer's specified value; the step often missed is verifying full insertion before tightening.

What maintenance or replacement will the Burndy lug need after extended service?

Periodically inspect the slotted screw for loosening and the aluminium body for oxidation or cracking; replace the lug if the conductor shows discolouration, the screw strips, or the tongue is deformed.

What limit appears first when the Burndy lug runs continuously at high load?

The 194 °F maximum operating temperature is the first limit reached under sustained current, so ensure ambient conditions and conductor sizing keep the connector below this threshold.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.