BFKK
BFKK USB-C Power Meter KWS-2303C 4-30V 0-12A
Measures USB-C voltage 4-30V and current 0-12A with curve recording and multi-protocol detection
- Accurate measurements within ±(1%+5) for reliable device testing
- Wide 4-30V and 0-12A range suits many USB-C peripherals
- Detects PD2.0/3.0, QC2.0/3.0, FCP, SCP, AFC, PE, DASH, VOOC and Super VOOC protocols
- Upgraded curve function records real-time voltage and current trends
- ISP colour display interface shows data clearly
USB-C Power Meter KWS-2303C
The BFKK KWS-2303C is a USB-C power meter that measures voltage from 4 to 30 volts and current up to 12 amps. It detects multiple fast-charging protocols including PD 2.0 and 3.0, QC 2.0 and 3.0, FCP, SCP, AFC, PE, DASH, VOOC and Super VOOC. A colour ISP display shows live readings and recorded curves.
For engineers, reviewers
This meter suits anyone who needs to verify charger output, power-bank capacity or cable performance across a wide voltage and current range. It is not intended for mains-voltage AC measurements, high-voltage DC work beyond 30 volts, or automated logging without manual display interaction.
Protocol detection breadth decides fit
The single specification that determines suitability is the range of supported fast-charge protocols. If the devices you test use PD, QC, FCP, SCP, AFC, PE, DASH, VOOC or Super VOOC, this meter will identify them; if your workflow requires other proprietary standards, it will not.
Highlights
- Accurate measurements within ±(1%+5) for reliable device testing
- Wide 4-30V and 0-12A range suits many USB-C peripherals
- Detects PD2.0/3.0, QC2.0/3.0, FCP, SCP, AFC, PE, DASH, VOOC and Super VOOC protocols
- Upgraded curve function records real-time voltage and current trends
- ISP colour display interface shows data clearly
Specifications
No published specifications for this item yet.
Questions about this item
How do I install the KWS-2303C inline between a charger and device, and which orientation mistake should I avoid?
Connect the tester's USB-C input to the power source and its USB-C output to the load; reversing them swaps source and load readings.
What maintenance or replacement will the KWS-2303C need over time?
No user-replaceable parts are specified; keep the ISP colour display clean and protect the 12A high-current terminal from debris.
What limit appears first during sustained high-current testing on the KWS-2303C?
The 12A current ceiling is reached before the 30V voltage limit when drawing maximum load continuously.