BFKK Oxygen Sensor Remover Alphasense O2-A2
Replacement oxygen sensor for BW Technologies gas detectors with 80 to 120 output at 20.9% O2 and 90 second response time
- Compatible with BW MicroClip XT, Max XT-II, Micro, Micro 5, Quattro, Max
- Output 80 to 120 at 20.9 % O2 for reliable detection
- Response time t90 90 s from 20.9 % to 0 % O2
- Replace sensor when ERR appears on O2 reading
- Brand new, sealed, latest manufactured by Alphasense
Direct Replacement Sensor
The Alphasense O2-A2 serves as a direct replacement oxygen sensor for BW Technologies GasAlert MicroClip XT, Max XT-II, Micro, Micro 5, Quattro and Max detectors. It restores accurate gas monitoring when the original cell shows an 'ERR' reading on the O2 display. Safety professionals and industrial hygienists rely on this component to maintain detector compliance.
Stable Output And Response
The sensor delivers an output of 80 to 120 at 20.9 % O2 concentration. Response time t90 is rated at 90 seconds when transitioning from 20.9 % to 0 % O2. These figures confirm reliable performance during normal atmospheric sampling and alarm conditions.
Ready For Immediate Installation
Each unit arrives brand new and sealed from the latest manufacturing run. No additional calibration accessories or software are bundled with the sensor. Users simply install the cell into the compatible BW Technologies detector and follow the instrument's standard calibration procedure.
Highlights
- Compatible with BW MicroClip XT, Max XT-II, Micro, Micro 5, Quattro, Max
- Output 80 to 120 at 20.9 % O2 for reliable detection
- Response time t90 90 s from 20.9 % to 0 % O2
- Replace sensor when ERR appears on O2 reading
- Brand new, sealed, latest manufactured by Alphasense
Specifications
No published specifications for this item yet.
Questions about this item
How do I install the Alphasense O2-A2 sensor into my BW Technologies GasAlert MicroClip XT?
Power off the detector, open the sensor bay, remove the old cell, insert the new O2-A2 matching the polarity marks, close the bay, then run a fresh air calibration at 20.9 % O2.
When will the Alphasense O2-A2 need replacement?
Replace the sensor when the display shows ERR in the O2 reading position, indicating the electrochemical cell is depleted.
What is the response-time limit of the O2-A2 under continuous monitoring?
The sensor reaches 90 % of the final reading within 80 to 120 seconds when oxygen drops from 20.9 % to zero.