BELL AND GOSSETT
BELL AND GOSSETT 62 Vacuum Breaker 3/4 in MNPT Brass 150 psi
Prevents back-siphonage with 3/4 in MNPT brass body rated 150 psi and 366 °F
- TypePipes, Valves & Fittings
- Prevents back-siphonage with 150 psi pressure rating
- Brass construction resists corrosion at 366 °F
- 3/4 in MNPT threads fit standard piping
- Compact 3 in height suits tight installations
- Model 62 delivers reliable vacuum-break performance
Bell & Gossett 62 Vacuum Breaker
The Bell & Gossett model 62 is a vacuum breaker designed for plumbing systems requiring backflow prevention. It features a 3/4 inch MNPT connection and brass construction rated for 150 psi maximum pressure. The unit operates within a temperature range up to 366 degrees Fahrenheit.
Installers needing code-compliant vacuum protection
This breaker suits contractors and maintenance teams fitting new or replacement valves on compatible pipework. It is not intended for systems exceeding the stated pressure or temperature limits. Buyers requiring different connection types or pressure ratings should look at alternative models.
Brass body with MNPT thread
The all-brass body provides corrosion resistance for long service life in potable water applications. The male NPT thread allows direct installation into standard female fittings without additional adapters. No extra accessories or software are included with this valve.
Highlights
- Prevents back-siphonage with 150 psi pressure rating
- Brass construction resists corrosion at 366 °F
- 3/4 in MNPT threads fit standard piping
- Compact 3 in height suits tight installations
- Model 62 delivers reliable vacuum-break performance
Specifications
| Brand | BELL & GOSSETT |
|---|---|
| Type | Pipes, Valves & Fittings |
Questions about this item
What pipe thread do I need on my existing supply line for the 3/4 in MNPT connection to seal properly?
You need a matching 3/4 in female NPT thread so the male MNPT end of the vacuum breaker can screw in and seal with thread tape or pipe dope.
Will the brass body and 150 psi rating handle the pressure spikes from my older well pump without leaking?
The brass construction and 150 psi maximum pressure rating are designed for typical residential supply pressures; normal well-pump cycles fall well within that limit.
After installation, how can I confirm the vacuum breaker is actually preventing back-siphonage?
With water flowing, shut off the downstream valve; you should hear a distinct click as the internal check seat opens to atmosphere, breaking the vacuum.