Beckett
Beckett CP651ULHTSP 115V Condensate Pump 212°F 65ft Lift
Removes condensate from high-lift installations up to 65 ft with water temperatures up to 212°F using a two-float design and hard-wired terminal block
- Handles high-lift installations up to 65 ft
- Operates with 115 V power supply
- Rated for condensate up to 212 °F
- Two-float design adds operational reliability
- Hard-wired terminal block simplifies installation
High-lift condensate pump
The Beckett CP651ULHTSP is a 115V condensate pump built for high-lift industrial installations up to 65 ft. It handles water temperatures up to 212°F and uses a hard-wired terminal block for power connection. A two-float design adds operational reliability for demanding plumbing environments.
Installers needing extreme vertical lift
This unit suits contractors and facility managers moving condensate over long vertical runs where standard pumps fall short. It is not intended for low-lift residential air-conditioning drains or applications that require a simple plug-in power cord instead of hard wiring.
Verify voltage and temperature limits
Confirm the supply circuit delivers 115V and that the condensate temperature will not exceed 212°F. Ensure the installation point can accommodate a hard-wired terminal block connection and that the required lift does not surpass 65 ft.
Highlights
- Handles high-lift installations up to 65 ft
- Operates with 115 V power supply
- Rated for condensate up to 212 °F
- Two-float design adds operational reliability
- Hard-wired terminal block simplifies installation
Specifications
| Brand | BECKETT |
|---|
Questions about this item
Does the Beckett CP651ULHTSP require a dedicated 115 V circuit and a hard-wired terminal block connection to operate?
Yes, the pump is rated for 115 V and power is supplied through a hard-wired terminal block, so an installer must provide a suitable circuit and wire directly to the block.
Can the pump handle condensate from a high-efficiency furnace that discharges water at temperatures near 212 °F?
The unit is rated for water temperatures up to 212 °F, making it suitable for high-temperature condensate from modern heating equipment.
After wiring and priming the pump, how can I verify the two-float system is cycling correctly at the rated 65 ft lift?
Fill the tank until the primary float activates the motor, confirm discharge at the 65 ft head, then allow the level to drop and ensure the secondary float provides redundant shut-off.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Taylor Made 12" x 18" Jolly Roger Novelty Flag 1818 marine electronic
- Accessories



