Banner
Banner AT-FM-10K Two-Hand Control Safety Relay 24 V 2 NO 6 A 22.5 mm
Safety relay module for two-hand control buttons with 24 V supply, 2 NO outputs at 6 A, 22.5 mm width and self-checking circuitry
- TypeTest Equipment
- Color/FinishRed
- Item Count1 pack
- Selling UnitBox
- Parts3 Years
- Labor1 Year
- Monitors two-hand controls for operator safety
- Runs on 24 V AC/DC with ±15 % tolerance
- Provides two normally-open safety contacts rated at 6 A
- Removable screw terminals in a 22.5 mm wide housing
- Self-checking circuitry responds in 35 ms maximum
Safety Relay for Two-Hand Control
The Banner AT-FM-10K is a safety relay module designed for two-hand control stations. It monitors complementary PNP or relay outputs from two buttons with a simultaneous operation window of 500 ms. The unit supplies 24 V ac/dc and provides two normally open safety outputs rated at 6 A. A removable screw terminal block simplifies wiring in a 22.5 mm wide housing.
Suited for Dual-Button Guarding.
This module suits machine builders who need a self-checking safety relay for a single pair of operator controls. It is not for installations that require additional safe outputs, auxiliary signalling contacts or expandable safety modules. Buyers needing LCD diagnostics or a wider terminal pitch should look at other designs.
22.5 mm Width Decides DIN-Rail Fit
The 22.5 mm width determines whether the relay fits the available DIN-rail space in the enclosure. The removable terminal block allows wiring before the module is snapped into place. Confirm the rail slot matches this dimension before ordering.
Highlights
- Monitors two-hand controls for operator safety
- Runs on 24 V AC/DC with ±15 % tolerance
- Provides two normally-open safety contacts rated at 6 A
- Removable screw terminals in a 22.5 mm wide housing
- Self-checking circuitry responds in 35 ms maximum
Specifications
| Brand | BANNER |
|---|---|
| Model | AT-FM-10K |
| Type | Test Equipment |
| Color/Finish | Red |
| Item Count | 1 pack |
| Selling Unit | Box |
| Parts | 3 Years |
| Labor | 1 Year |
Questions about this item
Should I choose the 22.5 mm wide version or a wider module?
The AT-FM-10K is 22.5 mm wide, fitting standard DIN-rail spacing; select it when panel space is limited.
What does the 6 A relay rating mean when the safety outputs switch a load?
Each of the two normally-open safety contacts can switch up to 6 A at the supply voltage, giving a combined safe switching capacity of 6 A per contact.
How does the 24 V ac/dc supply and 500 ms simultaneity window affect wiring?
The module accepts 24 V ac or dc (±15 %) and requires both input channels to close within 500 ms of each other for the safety outputs to energise.