We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Ashcroft

Ashcroft T27M0242EW200#GXCY Pressure Transducer 200 PSI

SKU CH-MHNR-R32EA

A 0–200 psi electronic pressure transducer with 4–20 mA output and ±0.25 % accuracy, IP66/NEMA 4X rated for –40 to 257 °F operation

  • TypeElectronic
  • 4-20 mA output enables long-distance signal transmission
  • ±0.25 % full-scale accuracy delivers precise pressure readings
  • 200 PSI range covers demanding hydraulic and pneumatic systems
  • NEMA 4X and IP66 ratings protect against dust and water ingress
  • 40 °F to 257 °F operating range suits extreme environments

200 PSI Pressure Transducer

The Ashcroft T27M0242EW200#GXCY is a 200 PSI electronic pressure transducer designed for test and measurement applications. It delivers a 4 to 20mA DC output signal with an accuracy of +/- 0.25 percent of full scale. The unit operates on a 9 to 36V DC supply using a two-wire loop-powered configuration. Its NEMA 4X and IP66 rated nylon housing suits harsh industrial environments.

M12 Connector and NPT Installation

Installation uses a male 1/4 inch NPT process connection that threads directly into a compatible port. The electrical interface is a 4-pin M12 connector requiring a matching cordset. Common issues include cross-threading the NPT fitting or applying excess torque that damages the nylon housing. Incorrect wiring of the two active pins on the M12 connector will prevent the 4 to 20mA signal from reaching the controller.

Verify Voltage Range and Temperature Limits

Confirm your system supplies between 9 and 36V DC to meet the transducer power requirement. Ensure the process media temperature stays within -40 to 257 degrees Fahrenheit to avoid sensor damage. Check that the 4 to 20mA input card accepts a two-wire transmitter and that the 1/4 inch NPT thread matches your existing port. The nylon housing material must be compatible with the measured media.

Highlights

  • 4-20 mA output enables long-distance signal transmission
  • ±0.25 % full-scale accuracy delivers precise pressure readings
  • 200 PSI range covers demanding hydraulic and pneumatic systems
  • NEMA 4X and IP66 ratings protect against dust and water ingress
  • 40 °F to 257 °F operating range suits extreme environments

Specifications

BrandASHCROFT
TypeElectronic

Questions about this item

How do I verify the transducer is reading correctly after installation?

Apply a known reference pressure and confirm the output current stays within 4 to 20 mA DC with an accuracy of ±0.25 % of the 200 psi full scale.

What ships with the transducer and what must I source separately?

The transducer itself is supplied; you must provide a 4-pin M12 mating cable and a 9 to 36 V DC power source.

Which pressure range should I select for my application?

Choose the 200 psi version when your maximum working pressure is at or below 200 psi; other ranges are different model numbers.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.