Ashcroft
Ashcroft K17M0242C1 60 psi Pressure Transmitter
Measures 0 to 60 psi with 4 to 20 mA output and +/-1% accuracy in a NEMA 4X, IP67 housing
- TypeElectronic
- Accurate 4–20 mA output with ±1 % full-scale precision
- 60 psi range covers low-pressure industrial and process applications
- 2-wire 10–36 V DC loop simplifies wiring and power
- NEMA 4X and IP67 ratings protect against water and dust ingress
- 20 °F to 180 °F operating span suits harsh environments
Industrial pressure transmitter for test
The Ashcroft K17M0242C1 is a new electronic pressure transmitter built for industrial test and measurement applications. It measures gauge pressure from 0 to 60 psi and delivers a 4 to 20mA DC output signal over a two-wire loop powered by 10 to 36V DC. The unit carries a NEMA 4X and IP67 rating for harsh environments.
Suits process monitoring with standard NPT fitting
This transmitter suits engineers and technicians who need a 1/4 in male NPT process connection and a 1/2 in MNPT conduit entry for fixed installations. Accuracy is specified at +/-1 percent of full scale across an operating range of -20 to 180 degrees F. Buyers requiring a different pressure range, alternate output protocol, or sanitary process connections should look at other models.
Handles 60 psi full scale with loop-powered headroom
The 60 psi upper limit provides headroom for typical hydraulic and pneumatic systems operating well below maximum scale. The 10 to 36V DC supply range accommodates common industrial loop voltages without external regulation. Operation beyond 60 psi or outside the stated temperature band exceeds the calibrated range and rated specifications.
Highlights
- Accurate 4–20 mA output with ±1 % full-scale precision
- 60 psi range covers low-pressure industrial and process applications
- 2-wire 10–36 V DC loop simplifies wiring and power
- NEMA 4X and IP67 ratings protect against water and dust ingress
- 20 °F to 180 °F operating span suits harsh environments
Specifications
| Brand | ASHCROFT |
|---|---|
| Type | Electronic |
Questions about this item
What power supply do I need to run the 4 to 20mA output loop?
A 10 to 36V DC source powers the two-wire loop that carries the 4 to 20mA signal.
Will the 1/4 in male NPT thread fit the female port on my existing manifold?
Yes, the process connection is a 1/4 in male NPT thread that mates with a standard female NPT port.
How can I verify the transmitter reads correctly after installation?
Apply 0 psi and confirm 4 mA, then apply 60 psi and confirm 20 mA; the reading should stay within ±1 % of full scale.