Ashcroft
Ashcroft K17M0242C1 30# Pressure Transducer
Measures 0 to 30 psi with 4 to 20mA output, NEMA 4X and IP67 rated for harsh environments
- TypeElectronic
- 0-30 psi range suits low-pressure monitoring
- 4-20 mA output enables long-distance signal transmission
- NEMA 4X and IP67 ratings protect against dust and water ingress
- 20 °F to 180 °F operating range handles extreme temperatures
- 2-wire loop-powered design simplifies installation wiring
Pressure transmitter for 30 psi range
The Ashcroft K17M0242C1 measures gauge pressure from 0 to 30 psi and outputs a 4 to 20 mA DC signal. It operates on a 10 to 36 V DC supply with a two-wire loop-powered design. Accuracy is rated at +/-1 percent of full scale. The housing carries NEMA 4X and IP67 ratings for dust and water protection.
Alloy steel construction and conduit entry
The wetted parts use alloy steel for compatibility with many industrial fluids. A 1/4 in male NPT process connection threads directly into standard ports. Wiring enters through a 1/2 in MNPT conduit connection with cable and wire leads provided. The transducer withstands ambient temperatures from -20 to 180 degrees F.
Suits fixed-range monitoring in harsh environments
This unit fits applications needing a dedicated 30 psi transmitter with rugged sealing and a standard current loop output. It is not suitable for users who require a different pressure span, a voltage output, a flush diaphragm or a field-adjustable range. Buyers needing higher over-pressure ratings or alternative process connections should consider other models.
Highlights
- 0-30 psi range suits low-pressure monitoring
- 4-20 mA output enables long-distance signal transmission
- NEMA 4X and IP67 ratings protect against dust and water ingress
- 20 °F to 180 °F operating range handles extreme temperatures
- 2-wire loop-powered design simplifies installation wiring
Specifications
| Brand | ASHCROFT |
|---|---|
| Type | Electronic |
Questions about this item
How often should the 1/4 in NPT process connection be inspected or replaced?
Inspect the 1/4 in NPT connection during routine calibration checks; replace if thread wear or seal degradation appears, typically after several years of service.
Which limit appears first during continuous operation — the 36 V DC supply ceiling or the 180 °F temperature ceiling?
The 180 °F maximum operating temperature is usually reached before the 36 V DC supply limit in high-ambient or high-process-temperature installations.
What heat rise should I expect from the 4 to 20 mA loop when the transmitter runs 24/7 at 30 psi?
Self-heating is minimal; the two-wire 4 to 20 mA loop draws little power, so case temperature stays close to ambient within the -20 °F to 180 °F rated range.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Lab Safety Supply Inc 667123 24 Well Tissue Culture Plate w/Lid PK50
- Assortments & Kits
Lab Safety Supply Inc 11L806 2mL Pipet Individually Wrapped PK600
- Assortments & Kits