Ashcroft
Ashcroft G2 Pressure Transducer -30 inHg to 30 psi
Measures vacuum to 30 psi with 4–20 mA output and ±0.5 % full-scale accuracy
- TypeElectronic
- 30 inHg to 30 psi range covers vacuum and pressure
- ±0.5 % full-scale accuracy for reliable readings
- 4-20 mA two-wire output simplifies wiring
- NEMA 4X and IP67 ratings resist water and dust
- 40 °F to 257 °F operating range handles extremes
G2 Pressure Transducer -30 inHg to 30 psi
The Ashcroft G2 pressure transducer measures vacuum and pressure from -30 inHg to 30 psi. It delivers a 4 to 20mA DC output signal with +/- 0.50 percent full-scale accuracy. The unit operates on 9 to 36V DC power and uses a two-wire connection. It is built for industrial test and measurement applications.
Suits process monitoring needing DIN 43650 Form
This transmitter fits systems requiring a DIN 43650 Form A electrical connector and a male 1/8 inch NPT process connection. It withstands temperatures from -40 to 257 degrees Fahrenheit. Buyers who need a different output protocol, a larger process thread, or a higher pressure range should look at other models.
Verify your supply voltage and port compatibility
Confirm your system provides 9 to 36V DC supply voltage for the two-wire loop. Ensure the panel or enclosure accepts a DIN 43650 Form A plug and a male 1/8 inch NPT fitting. Check that the -30 inHg to 30 psi range matches your measurement requirements before ordering.
Highlights
- 30 inHg to 30 psi range covers vacuum and pressure
- ±0.5 % full-scale accuracy for reliable readings
- 4-20 mA two-wire output simplifies wiring
- NEMA 4X and IP67 ratings resist water and dust
- 40 °F to 257 °F operating range handles extremes
Specifications
| Brand | ASHCROFT |
|---|---|
| Type | Electronic |
Questions about this item
What power supply range must I already have to run the G2 transducer?
The G2 requires a 9 to 36V DC supply; any source within that range will power the 4 to 20mA loop.
Will the 1/8 in male NPT process connection fit the legacy port on my existing manifold?
Yes, the G2 uses a standard 1/8 in male NPT thread, so it mates directly with any matching female NPT port.
How do I confirm the 4 to 20mA output is tracking pressure correctly after installation?
Apply known vacuum and pressure across the -15 to 30 psi span and verify the loop current moves proportionally within the ±0.50 % full-scale accuracy.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Lab Safety Supply Inc 667123 24 Well Tissue Culture Plate w/Lid PK50
- Assortments & Kits
Lab Safety Supply Inc 11L806 2mL Pipet Individually Wrapped PK600
- Assortments & Kits