Ashcroft
Ashcroft G2 0-200 psi 1-5V DC Transducer
Measures 0 to 200 psi and outputs 1 to 5V DC with ±0.50% full-scale accuracy, NEMA 4X and IP67 sealing, and a 9 to 36V DC supply range
- TypeElectronic
- Measures 0 to 200 psi for wide industrial range
- 1 to 5 V DC output integrates with standard control systems
- ±0.50 % full-scale accuracy ensures reliable readings
- NEMA 4X and IP67 ratings withstand harsh environments
- Operates from -40 °F to 257 °F for extreme conditions
Pressure Transducer for Industrial Systems
The Ashcroft G2 transducer converts 0 to 200 psi into a 1 to 5V DC signal for data acquisition and control loops. It suits process engineers and maintenance teams who need a compact transmitter with a 1/4 in male NPT connection. The three-wire design simplifies wiring into existing 9 to 36V DC supplies.
Thermal Limits and Electrical Protection
The nylon housing meets NEMA 4X and IP67 ratings for wash-down and immersion resistance. Operating temperatures span -40 to 257 degrees F, covering outdoor and high-ambient installations. Accuracy holds to +/- 0.50 percent of full scale across the range without active cooling.
Upgrade Path From Basic Switches
This unit replaces mechanical pressure switches where continuous analogue feedback is required. The jump is worth it when PLCs or SCADA systems need real-time trending instead of discrete trip points. Buyers who only need on-off actuation at a single setpoint will not benefit from the added signal complexity.
Highlights
- Measures 0 to 200 psi for wide industrial range
- 1 to 5 V DC output integrates with standard control systems
- ±0.50 % full-scale accuracy ensures reliable readings
- NEMA 4X and IP67 ratings withstand harsh environments
- Operates from -40 °F to 257 °F for extreme conditions
Specifications
| Brand | ASHCROFT |
|---|---|
| Type | Electronic |
Questions about this item
How do I wire the three leads for the 1 to 5V DC output and 9 to 36V DC supply?
Connect the supply positive to the 9 to 36V DC input, supply negative to common, and the signal lead to your 1 to 5V DC input; the third wire is the shared return.
Will the nylon housing or NEMA 4X and IP67 seals need periodic replacement?
The nylon housing and factory seals are rated for the full -40 to 257 Degrees F range; no scheduled seal or housing replacement is required.
At what pressure does the +/- 0.50 Percent Full Scale accuracy limit become the dominant error?
The +/- 0.50 Percent Full Scale specification applies across the entire 0 to 200 psi span, so it is the governing accuracy limit at every reading.