Ashcroft
Ashcroft G17M0242F23000# Pressure Transducer 0-3000 psi
Measures pressure from 0 to 3000 psi with a 4 to 20mA output and +/- 0.50% accuracy, housed in NEMA 4X and IP67 rated Nylon for -40 to 257°F operation
- TypeElectronic
- Measures up to 3000 psi for high-pressure systems
- Outputs 4 to 20 mA DC for reliable signal transmission
- Accuracy of ±0.50% full scale ensures precise readings
- IP67 and NEMA 4X ratings protect against dust and water ingress
- Operates from -40°F to 257°F for extreme environments
Ashcroft G1 0-3000 psi Transducer
The Ashcroft G1 pressure transducer measures gauge pressure from 0 to 3000 psi and outputs a 4 to 20 mA DC signal. It is built for technicians and engineers who need a compact, two-wire transmitter for hydraulic or pneumatic test rigs. The NPT male process connection and cable leads allow direct installation without extra fittings.
4-20 mA Loop 9-36 V DC Supply
The current-loop output requires a 9 to 36 V DC supply and a series load resistor at the receiver to convert current into a measurable voltage. Accuracy is specified as ±0.50 % of full scale across the -40 °F to 257 °F operating range. Long cable runs or high loop resistance can reduce available voltage at the transducer and must be checked against the supply.
NEMA 4X IP67 Nylon Housing
The nylon housing carries NEMA 4X and IP67 ratings, so the unit withstands wash-down, dust and temporary immersion in harsh industrial environments. Buyers who need a stainless-steel wetted part or a flush diaphragm for viscous media should verify material compatibility before ordering.
Highlights
- Measures up to 3000 psi for high-pressure systems
- Outputs 4 to 20 mA DC for reliable signal transmission
- Accuracy of ±0.50% full scale ensures precise readings
- IP67 and NEMA 4X ratings protect against dust and water ingress
- Operates from -40°F to 257°F for extreme environments
Specifications
| Brand | ASHCROFT |
|---|---|
| Type | Electronic |
Questions about this item
Which pressure range should I select for my application?
This transducer covers 0 to 3000 psi with a 4 to 20 mA output loop powered from 9 to 36 V DC.
What does the ±0.50 % full-scale accuracy mean in practice?
The maximum error is ±0.50 % of 3000 psi, so readings stay within that band across the entire span.
How does the 4 to 20 mA loop and NPT connection limit installation?
Two-wire 4 to 20 mA needs a 9 to 36 V DC supply and a 1/4 in male NPT process port; NEMA 4X and IP67 ratings suit harsh environments.