Ashcroft
Ashcroft G17M0242F2300# Pressure Transducer 0-300 psi
Measures 0–300 psi with 4–20 mA output, ±0.50 % full-scale accuracy, 1/4 in NPT male fitting, IP67 and NEMA 4X sealing, operating from −40 °F to 257 °F on 9–36 V DC
- TypeElectronic
- 4–20 mA output suits industrial control loops
- ±0.50 % full-scale accuracy for reliable readings
- NEMA 4X and IP67 ratings resist dust and water
- 40 to 257 °F operating range handles extreme environments
- 9–36 V DC supply works with common panel power
Range and Output
The Ashcroft G2 series transducer measures gauge pressure from 0 to 300 psi and delivers a 4 to 20 mA DC signal. It operates on a 9 to 36 V DC supply using a two-wire loop-powered design. The sensor suits industrial monitoring where a reliable current loop is required.
Electrical and Process Fit
Verify that your system accepts a 4 to 20 mA input and can provide 9 to 36 V DC to the transmitter. The process connection is a male 1/4 in NPT thread; confirm thread compatibility and sealing method before installation. Cable and wire leads are supplied for electrical termination.
Environmental Tolerance
The nylon housing carries NEMA 4X and IP67 ratings for dust and water ingress protection. Operating temperature spans -40 °F to 257 °F, allowing use in harsh ambient conditions. Accuracy is specified at ±0.50 percent of full scale across the compensated range.
Highlights
- 4–20 mA output suits industrial control loops
- ±0.50 % full-scale accuracy for reliable readings
- NEMA 4X and IP67 ratings resist dust and water
- 40 to 257 °F operating range handles extreme environments
- 9–36 V DC supply works with common panel power
Specifications
| Brand | ASHCROFT |
|---|---|
| Type | Electronic |
Questions about this item
What comes with the G17M0242F2300# transducer and what must I supply?
The unit ships with integral cable leads for the 4 to 20mA DC output. You must provide a 9 to 36V DC power source and a 1/4 in NPT male process fitting.
How do I choose between the available pressure ranges for this model?
This specific model is fixed at a 0 to 300 psi range. If your application requires a different span, a separate part number from the G2 series would be needed.
What does the +/- 0.50 percent full-scale accuracy mean on a live 300 psi system?
At full scale the reading can deviate by up to 1.5 psi. Across the 0 to 300 psi span the maximum error remains within that 1.5 psi band.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Lab Safety Supply Inc 667123 24 Well Tissue Culture Plate w/Lid PK50
- Assortments & Kits
Lab Safety Supply Inc 11L806 2mL Pipet Individually Wrapped PK600
- Assortments & Kits