Ashcroft
Ashcroft 35 1005P XUL 02L 80# Pressure Gauge
Measures air pressure from 0 to 80 psi with a 3½-inch dial and ¼-inch NPT male connection
- TypeFacility & Worksite Safety
- Accurate readings with ±3-2-3% precision
- 0 to 80 psi range suits fire sprinkler systems
- 3 1/2 inch dial for clear visibility
- 1/4 inch NPT male connection for standard fittings
- Durable ABS plastic case with polycarbonate lens
Fire Sprinkler Gauge
The Ashcroft 35 1005P XUL 02L is a commercial pressure gauge designed for fire sprinkler system monitoring. It suits facility managers and safety technicians who need reliable pressure indication for air-based systems. The gauge provides a clear visual reading on a white dial with a black ABS plastic case.
0 to 80 psi Range
The primary pressure range spans 0 to 80 psi, which is the critical specification for matching system requirements. Accuracy follows a +/-3-2-3 percent grade across the scale. The 1/4 in male NPT bottom connection ensures direct installation into standard sprinkler piping without additional adapters.
Sustained Static Monitoring
Under continuous system pressure the polycarbonate lens and ABS case resist environmental exposure in facility settings. The dry, non-liquid-filled movement eliminates the risk of fluid leaks during long-term service. This gauge is not field fillable and carries no IP or NEMA rating, so it is unsuited for wash-down areas or outdoor exposure without a protective enclosure.
Highlights
- Accurate readings with ±3-2-3% precision
- 0 to 80 psi range suits fire sprinkler systems
- 3 1/2 inch dial for clear visibility
- 1/4 inch NPT male connection for standard fittings
- Durable ABS plastic case with polycarbonate lens
Specifications
| Brand | ASHCROFT |
|---|---|
| Type | Facility & Worksite Safety |
Questions about this item
What does the 80 psi range mean when the gauge is installed on a fire sprinkler system?
It shows the system pressure from zero up to 80 psi with a commercial-grade accuracy of plus or minus 3-2-3 percent across the dial.
How does the 1/4 inch NPT male connection limit what piping I can attach?
The bottom-mounted male NPT thread only fits female 1/4 inch NPT fittings; other thread sizes or types will not seal without an adapter.
Will the 3 1/2 inch ABS case and polycarbonate lens fit the standard panel cut-out on my sprinkler riser?
The nominal 3 1/2 inch dial size determines the panel opening; the black ABS case and polycarbonate lens mount through that cut-out with the connection at the bottom.