Ashcroft
Ashcroft 30-1084S 02L 200 PSI Test Pressure Gauge
Measures 0 to 200 psi with ±0.50 % accuracy on a 3 in stainless-steel dial
- Color/FinishStainless Steel
- TypeElectronic
- +/- 0.50 % accuracy for precise readings
- 316L stainless steel case resists corrosion
- 0 to 200 psi range covers broad test needs
- 3 in dial with mirror band reduces parallax
- 1/4 in NPT male connection fits standard ports
Test Pressure Gauge for 0-200 psi Systems
This Ashcroft 30-1084S 02L test pressure gauge measures pressure from 0 to 200 psi with a +/- 0.50 percent accuracy rating. It features a 3 in nominal dial size with a white mirror-band face for precise reading. The gauge case is constructed from 316L stainless steel for corrosion resistance.
Capacity and Headroom for Process Monitoring
The primary pressure range covers applications requiring measurement up to 200 psi with high accuracy. The +/- 0.50 percent full-scale accuracy provides reliable data for critical testing and calibration tasks. The polycarbonate lens protects the dial while maintaining clear visibility of the mirrored scale.
Integration Requirements for NPT Installations
The gauge connects via a 1/4 in male NPT bottom process connection, requiring a compatible female port. The 316L stainless steel wetted parts suit compatible media, though the case is not liquid-filled and carries no IP or NEMA rating. Panel mounting is not supported, so the gauge installs directly into the process line.
Highlights
- +/- 0.50 % accuracy for precise readings
- 316L stainless steel case resists corrosion
- 0 to 200 psi range covers broad test needs
- 3 in dial with mirror band reduces parallax
- 1/4 in NPT male connection fits standard ports
Specifications
| Brand | ASHCROFT |
|---|---|
| Color/Finish | Stainless Steel |
| Type | Electronic |
Questions about this item
Will the 1/4 in NPT male connection thread directly into the 1/4 in ports on my existing manifold?
Yes, the gauge uses a 1/4 in NPT male process connection that matches standard 1/4 in NPT female ports on most manifolds.
How can I verify the +/- 0.50 percent accuracy on the 0 to 200 psi dial after installation?
Apply a known reference pressure at several points across the 0 to 200 psi range and confirm the pointer stays within half a percent of full scale at each point.
Does the 316L stainless steel case arrive filled with liquid or do I need to purchase fill fluid separately?
The case is not liquid-filled and is not field-fillable, so no fill fluid is required or used with this gauge.