ARENTI
ARENTI 2 in 1 accessory Cat6 500ft 26AWG shielded outdoor
Cat6 shielded bulk cable with 26AWG CCA conductors, cross-skeleton separator and UV-resistant jacket rated for direct burial and 550 MHz bandwidth over 500 ft
- Stable data transmission from cross-skeleton 26AWG CCA twisted pairs
- Reliable outdoor performance in extreme heat or freezing cold
- Direct burial rated sheath eliminates conduit and tripping hazards
- Cut to custom length for RJ45 connector compatibility
- 550 MHz bandwidth supports high-speed network connections
26AWG Shielded Cat6 Cable 500ft
This 500ft bulk Cat6 cable uses four 26AWG copper-clad aluminium twisted pairs with a cross-skeleton separator to limit EMI and RFI. A UV-resistant, waterproof jacket is rated for direct burial so no conduit is required. The cable is terminated without RJ45 connectors for custom-length runs.
Upgrade from Unshielded or Indoor Cable
Replacing unshielded or indoor-rated cable with this shielded outdoor version is worthwhile when the run passes near power lines, fluorescent lighting or any source of electromagnetic noise. The direct-burial rating also removes the cost and labour of conduit for underground paths.
Verify Connector and Tool Compatibility
Ensure you have RJ45 plugs rated for 26AWG stranded conductors and a crimp tool that matches those plugs. The cross-skeleton separator adds bulk, so confirm your connector housing accommodates the cable diameter before cutting the 500ft reel.
Highlights
- Stable data transmission from cross-skeleton 26AWG CCA twisted pairs
- Reliable outdoor performance in extreme heat or freezing cold
- Direct burial rated sheath eliminates conduit and tripping hazards
- Cut to custom length for RJ45 connector compatibility
- 550 MHz bandwidth supports high-speed network connections
Specifications
No published specifications for this item yet.
Questions about this item
What trench depth or conduit size does the 500 ft outdoor Cat6 cable need for direct burial?
The cable is rated for direct burial without conduit, so no specific trench depth or conduit size is required by the product itself. Follow local building codes for depth.
How do I terminate the 26 AWG CCA conductors with RJ45 plugs, and what step causes most failures?
Use RJ45 connectors designed for 26 AWG stranded CCA wire, strip the cross-skeleton carefully, and fully seat each conductor before crimping; the most common failure is using standard solid-wire plugs.
When should I replace the UV-resistant sheath on a 550 MHz Cat6 run?
Inspect the jacket annually for cracking or chalking from UV exposure; replace the cable if the sheath shows degradation or if water ingress affects the shielded pairs.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.



