Appleton Century Crofts
Appleton Century Crofts UNY75NR-A Rigid Union Conduit 3/4 in Threaded Aluminum Plain
A 3/4 in rigid conduit union with female-to-male NPT threads and hazardous-location ratings for Class I, II and III divisions
- TypeCable Management & Conduit
- Connects rigid conduit to enclosures with 3/4 in FNPT x 3/4 in MNPT ends
- Rated for hazardous locations Class I Div 1&2 Groups A B C D
- Aluminum construction with plain finish resists corrosion in tough environments
- Compact 2 3/16 in overall length fits tight installation spaces
- Straight union design allows vertical or horizontal rigid conduit runs
Rigid Union for 3/4 in Conduit
The Appleton Century Crofts UNY75NR-A is a straight union designed to join rigid conduit to a box in hazardous locations. It suits electricians and maintenance teams who need a reliable transition between 3/4 in female and male NPT threads.
Sustained Performance in Hazardous Areas
The aluminum body with a plain finish resists corrosion in Class I, Division 1 and 2 environments covering Groups A, B, C, D and Class II, Division 1 and 2 Groups E, F, G as well as Class III. It maintains its thread integrity and grounding path under continuous vibration and thermal cycling where lesser fittings loosen.
Simple Threaded Installation
Installers tighten the 3/4 in FNPT and MNPT ends with standard wrenches; no special tools or compounds are required. The most common error is cross-threading the tapered NPT joints, which can compromise the hazardous-location seal and require complete replacement.
Highlights
- Connects rigid conduit to enclosures with 3/4 in FNPT x 3/4 in MNPT ends
- Rated for hazardous locations Class I Div 1&2 Groups A B C D
- Aluminum construction with plain finish resists corrosion in tough environments
- Compact 2 3/16 in overall length fits tight installation spaces
- Straight union design allows vertical or horizontal rigid conduit runs
Specifications
| Brand | APPLETON ELECTRIC |
|---|---|
| Type | Cable Management & Conduit |
Questions about this item
Does the aluminum body of the UNY75NR-A run hot when conduit carries heavy loads all day?
The fitting is a passive aluminum union with no electrical load, so it does not generate heat during continuous operation.
What conduit and box threads must already be on site for this 3/4 in union to connect?
You need 3/4 in rigid conduit with male NPT ends and a box or fitting with a 3/4 in female NPT opening.
Will the Class I Division 1 rating on this union match the older hazardous-location boxes we already have?
Yes, the UNY75NR-A carries Class I Division 1 and 2, Groups A–D, and Class II Division 1 and 2, Groups E–G, matching legacy fittings with the same ratings.