Appleton Century Crofts
Appleton Century Crofts Reducing Bushing 4 in x 2 in Threaded Iron
Threaded iron reducing bushing connects 4-inch to 2-inch conduit in hazardous locations
- TypeCable Management & Conduit
- Reduces conduit from 4 in to 2 in with threaded iron construction
- Chromate, powder and electroplated finish resists corrosion in harsh environments
- Rated for Class I Div 1 & 2 hazardous locations
- Female to male NPT threads ensure secure, code-compliant connections
- Weighs 1.65 lb for solid, reliable installation
Threaded Iron Reducing Bushing
This Appleton Century Crofts reducing bushing connects 4 inch and 2 inch threaded conduit in hazardous locations. The iron construction features chromate, powder and electroplated finishes. It carries Class I Division 1 and 2, Class II Division 1 and 2 and Class III ratings for demanding environments.
Installers needing hazardous-location conduit
Suited for electricians joining IMC or threaded RMC of different trade sizes in classified areas. The female-to-male NPT ends simplify field assembly. Not for installers who require non-threaded coupling methods or conduit sizes outside the 2 inch to 4 inch range.
1 7/16 inch overall length
The bushing measures 1 7/16 inches long and weighs 1.65 pounds. This compact length determines whether it fits within the available enclosure space. Verify the dimension against your layout before ordering.
Highlights
- Reduces conduit from 4 in to 2 in with threaded iron construction
- Chromate, powder and electroplated finish resists corrosion in harsh environments
- Rated for Class I Div 1 & 2 hazardous locations
- Female to male NPT threads ensure secure, code-compliant connections
- Weighs 1.65 lb for solid, reliable installation
Specifications
| Type | Cable Management & Conduit |
|---|---|
| Brand | APPLETON ELECTRIC |
Questions about this item
What conduit sizes must already be installed to connect with the 4 in x 2 in reducing bushing?
The bushing joins a 4 in male-threaded conduit to a 2 in female-threaded conduit, so both trade sizes must be present.
Can the chromate, powder-coated and electroplated iron bushing be used with existing galvanised rigid metal conduit?
Yes, it is compatible with threaded RMC and IMC, so it threads directly onto standard galvanised rigid metal conduit of the same trade sizes.
How can I verify the hazardous-location rating is correct after installation?
Confirm the Class I Division 1 and 2, Groups B, C, D and Class II Division 1 and 2, Groups E, F, G markings are visible on the fitted bushing.