Appleton Century Crofts
Appleton Century Crofts APP870IG Conduit Body Cover video accessory
A steel conduit-body cover with gasket and screws for Appleton FM7 fittings in hazardous locations, UL listed for Class I Division 2
- TypeCable Management & Conduit
- ColorTransparent
- UL Listed for Class I Division 2 hazardous locations
- Steel construction with included gasket seals conduit bodies
- Screw-in cover fits 2-1/2 and 3 inch hubs
- Designed specifically for Appleton FM7 series fittings
- New condition ensures reliable conduit access protection
Conduit body cover for FM7 fittings
The Appleton Century Crofts APP870IG is a steel cover designed for FM7 Unilet conduit outlet bodies. It fits hub sizes of 2 1/2 in and 3 in and includes a gasket and screws for a screw-in connection. The cover is UL Listed E2527 for Class I, Division 2 hazardous locations. Supplied new and finished in transparent colour.
Gasket and screws simplify installation
The bundled gasket provides the seal required for the hazardous-location rating without sourcing a separate part. Included screws match the screw-in connection type so the cover can be fitted immediately. Both accessories are specified for the FM7 series and the stated hub sizes.
Suits electricians sealing FM7 bodies in Class I
Installers who need a listed cover with hardware included for 2 1/2 in or 3 in hubs will find this part matches the specification. Buyers who want a different hub size, a non-metallic cover, or a fitting without the hazardous-location rating should look at something else.
Highlights
- UL Listed for Class I Division 2 hazardous locations
- Steel construction with included gasket seals conduit bodies
- Screw-in cover fits 2-1/2 and 3 inch hubs
- Designed specifically for Appleton FM7 series fittings
- New condition ensures reliable conduit access protection
Specifications
| Brand | APPLETON ELECTRIC |
|---|---|
| Type | Cable Management & Conduit |
| Color | Transparent |
Questions about this item
Will the gasket need replacing after extended use in a hazardous location?
The cover includes a gasket and screws for installation; replacement timing depends on operating conditions and inspection schedules.
What temperature or load limit is reached first during continuous operation in a Class I Division 2 area?
The cover is UL Listed E2527 for Class I Division 2 hazardous locations; specific thermal or load limits are defined by the conduit body rating.
Does the steel cover generate noticeable heat or require extra power when installed on an FM7 conduit body all day?
The steel cover is a passive accessory with no power draw; it does not generate heat beyond ambient conditions inside the conduit system.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.