Appleton Century Crofts
Appleton Century Crofts APP670IGSA Conduit Body Cover 2In Alum FM7
Aluminium cover with gasket and screws for 2 in FM7 conduit bodies, UL listed for Class I Division 2 hazardous locations
- TypeCable Management & Conduit
- ColorTransparent
- Aluminium construction resists corrosion in harsh environments
- UL Listed E2527 for Class I Division 2 hazardous locations
- Screw-in connection with included gasket seals conduit bodies
- Supplied screws and gasket enable immediate installation
- Designed specifically for Appleton FM7 2-inch conduit bodies
Conduit Body Cover 2In Alum FM7
The Appleton Century Crofts APP670IGSA is an aluminum cover designed for FM7 Unilet conduit outlet bodies with a 2 in hub size. It serves electrical installers who need to close off conduit access fittings in hazardous locations rated Class I Division 2.
UL Listed E2527 with Gasket and Screws
The cover includes a gasket and mounting screws so the fitting remains sealed against moisture and contaminants. UL Listing E2527 confirms compliance for Class I Division 2 areas, and the screw-in connection allows secure attachment without additional hardware.
Aluminum Material and Screw-In Connection Limits
Aluminum construction provides corrosion resistance but is not suited for direct burial or extreme impact environments. The screw-in interface requires matching FM7 series threads, so the cover cannot be used on conduit bodies with different thread profiles or hub sizes.
Highlights
- Aluminium construction resists corrosion in harsh environments
- UL Listed E2527 for Class I Division 2 hazardous locations
- Screw-in connection with included gasket seals conduit bodies
- Supplied screws and gasket enable immediate installation
- Designed specifically for Appleton FM7 2-inch conduit bodies
Specifications
| Brand | APPLETON ELECTRIC |
|---|---|
| Type | Cable Management & Conduit |
| Color | Transparent |
Questions about this item
Will the gasket need replacement after long-term exposure?
The cover includes a gasket rated for Class I Division 2 hazardous locations. Replacement timing depends on site conditions and inspection schedules.
What limits continuous operation in a Class I Division 2 area?
The UL Listed E2527 rating for Class I Division 2 defines the hazardous-location limit. The cover must remain sealed and undamaged to maintain that rating.
Does the aluminum cover run hot when conduit carries full load all day?
The cover is a passive aluminum enclosure with no internal power dissipation. Conductor temperature depends on wire size, load and ambient conditions, not the cover itself.