APC SRTL5KRM2UT UPS 5KVA/5KW 2U 208V 1.50h 2xL6-30R 2xL6-20R
On-line lithium-ion UPS delivering 5 kVA/5 kW in a 2U rack/tower with 208 V input/output, two L6-30R and two L6-20R outlets, and a 1.50-hour recharge
- 5 kVA/5 kW on-line protection in 2U rack/tower
- 50 hour recharge cuts downtime after outages
- 208 V input/output matches data-centre power
- Two L6-30R outlets handle 30 A loads
- Two L6-20R outlets support 20 A equipment
5 kVA lithium-ion UPS for rack or tower
The APC SRTL5KRM2UT is a 5 kVA / 5 kW on-line lithium-ion uninterruptible power supply in a 2U rack or tower form factor. It accepts 208 V AC input and delivers 208 V AC output. The unit is aimed at IT managers protecting servers, network gear or storage arrays that require continuous double-conversion power.
Check 208 V supply and outlet types
Before ordering, confirm the site provides a 208 V AC source and that the distribution panel can feed the unit. The UPS offers two NEMA L6-30R and two NEMA L6-20R receptacles; verify that each connected device uses a matching plug or that suitable adapters are available. Ensure rack depth and mounting rails suit a 2U device.
1.50 hour recharge reduces exposure
The lithium-ion battery reaches full charge in 1.50 hours, shortening the window of reduced runtime after an outage. This fast recharge helps maintain protection for critical loads during repeated power events. No additional software or accessories are described in the supplied data.
Highlights
- 5 kVA/5 kW on-line protection in 2U rack/tower
- 50 hour recharge cuts downtime after outages
- 208 V input/output matches data-centre power
- Two L6-30R outlets handle 30 A loads
- Two L6-20R outlets support 20 A equipment
Specifications
No published specifications for this item yet.
Questions about this item
Does the unit ship with the NEMA L6-30R and L6-20R output cords or must they be purchased separately?
The UPS includes two NEMA L6-30R and two NEMA L6-20R receptacles built into the chassis; no separate output cords are required for basic connection.
Is the 5 kVA / 5 kW rating the only capacity offered for this 2U lithium-ion model?
The listed model SRTL5KRM2UT provides a single 5 kVA / 5 kW capacity; other capacities would carry different model numbers.
With a 1.50 hour recharge time, how quickly will the battery be ready after a full discharge?
The internal lithium-ion battery reaches full charge in 1.50 hours, so the UPS restores its full runtime within that window after a complete discharge.