We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

APC

APC Basic Rack 2.4kVA PDU AP9564 10x NEMA L5-20R 1U

SKU CH-XS60-ZGJJC

Distributes 2.4 kVA at 120 V through ten NEMA L5-20R outlets in a 1U rack-mount unit with a 12 ft input cord

  • Weight6.1
  • Distributes power to rack equipment via 10 NEMA L5-20R outlets
  • 4 kVA capacity supports demanding 120 V AC loads
  • Tool-free vertical mounting in NetShelter VX rear channels
  • Compact 1U height fits standard 17.6 in rack width
  • 12 ft input cord with NEMA L5-20P plug reaches distant sources

Basic Rack 2.4 kVA PDU

The APC Basic Rack PDU distributes 120 V AC power to rack mounted equipment from a single NEMA L5-20P input. It provides ten NEMA L5-20R outlets rated for 2.4 kVA total capacity. The unit suits server rooms and network closets that need reliable outlet distribution in a compact form.

Tool less vertical mounting in NetShelter VX

The 1U high chassis measures 1.8 by 17.6 by 2.3 inches and weighs 5.50 lb. It mounts vertically in the rear channel of a NetShelter VX enclosure without tools using the included brackets. A 12 foot input cord reaches nearby power sources while the black finish matches standard rack aesthetics.

2.4 kVA limit on 120 V circuits

The 2.40 kVA rating sets the maximum combined load across all ten outlets. Each NEMA L5-20R receptacle supports locking plugs but the aggregate draw must stay within the 20 A branch circuit. Installations requiring higher density or three phase power need a different PDU model.

Highlights

  • Distributes power to rack equipment via 10 NEMA L5-20R outlets
  • 4 kVA capacity supports demanding 120 V AC loads
  • Tool-free vertical mounting in NetShelter VX rear channels
  • Compact 1U height fits standard 17.6 in rack width
  • 12 ft input cord with NEMA L5-20P plug reaches distant sources

Specifications

BrandSchneider Electric
ModelAP9564
Weight6.1

Questions about this item

What input plug does the AP9564 PDU use and what current does it support?

It uses a NEMA L5-20P plug rated for 20 A at 120 V AC, capping usable power at 2.40 kVA.

What rack depth and height does the 1U unit require?

The PDU is 17.6 in wide, 2.3 in deep and 1.8 in high, fitting a standard 1U vertical channel.

How is the AP9564 mounted and which step is often missed?

Tool-less brackets clip into the rear NetShelter VX channel; the step often missed is fully seating both brackets until they click.